APPARATUS CASE AND CONTROL UNITS

EPC / Mercedes / Car / FG / FG 251.125 / 54 / 080
№- Nazwa I* Numer części
010 HOUSING
APPARATUS CASE

ONLY VALID WITH EQUIPMENT:
104A/204A/504A
001 A 251 540 05 24
020 GROMMET
TO EQUIPMENT COMPARTMENT
001 A 129 997 49 81
030 COVER
APPARATUS CASE

ONLY VALID WITH EQUIPMENT:
104A/204A/504A
001 A 164 540 01 82
040 RELAY UNIT
IN EQUIPMENT COMPARTMENT

001 A 164 540 29 72
040 RELAY UNIT
IN EQUIPMENT COMPARTMENT

OBSERVE WORK INSTRUCTIONS IN WIS WIS-NET#GF40.10-P-0804B#
001 A 164 540 32 72
040 RELAY UNIT
IN EQUIPMENT COMPARTMENT

001 A 164 540 35 72
040 RELAY
IN EQUIPMENT COMPARTMENT

001 A 164 540 38 72
040 RELAY
IN EQUIPMENT COMPARTMENT
001 A 164 982 03 23
040 RELAY UNIT
IN EQUIPMENT COMPARTMENT

OBSERVE WORK INSTRUCTIONS IN WIS WIS-NET#GF40.10-P-0804B#
001 A 164 540 34 72
040 RELAY UNIT
IN EQUIPMENT COMPARTMENT

001 A 164 540 34 72
040 RELAY
IN EQUIPMENT COMPARTMENT

Zastąpiono przez: A 164 982 02 23
001 A 164 540 37 72
040 RELAY
IN EQUIPMENT COMPARTMENT
001 A 164 982 02 23
045 RELAY
PLUG POSITION: A
001 A 002 542 74 19
045 RELAY
PLUG POSITION: B
001 A 002 542 74 19
045 RELAY
PLUG POSITION: C
001 A 002 542 11 19
045 RELAY
PLUG POSITION: F
001 A 002 542 11 19
045 RELAY
PLUG POSITION: G
001 A 002 542 23 19
045 RELAY
PLUG POSITION: I
001 A 002 542 23 19
045 RELAY
PLUG POSITION: D
001 A 002 542 26 19
045 RELAY
PLUG POSITION: E
001 A 002 542 26 19
045 RELAY
PLUG POSITION: H
001 A 002 542 26 19
045 RELAY
STARTING CONTROL
001 A 002 542 23 19
045 RELAY
COMPRESSOR
001 A 002 542 23 19
150 HOUSING
APPARATUS CASE
001 A 251 540 07 24
150 EQUIPMENT BOX
APPARATUS CASE

OBSERVE WORK INSTRUCTIONS IN WIS WIS-NET#GF40.10-P-0804B#
001 A 251 545 00 01
150 EQUIPMENT BOX
001 A 251 545 01 01
170 COVER
APPARATUS CASE
001 A 251 540 04 82
180 HEXAGON NUT W COLLAR
MOUNTING, EQUIPMENT BOX 5 MM
003 A 210 990 01 50
190 RUBBER MOUNT
APPARATUS CASE TO BRACKET

ONLY VALID WITH EQUIPMENT:
104A/204A/504A
002 A 203 504 02 12
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
Zastąpiono przez: A 164 540 65 01
001 A 164 540 46 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
Zastąpiono przez: A 164 540 81 01
001 A 164 540 65 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
Zastąpiono przez: A 164 440 38 01
001 A 164 540 81 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
001 A 164 440 38 01
200 CONTROL UNIT
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE


PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
Zastąpiono przez: A 164 900 41 01
001 A 164 900 35 01
200 CONTROL UNIT
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE


PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
PART IS ONLY OR ALSO SUPPLIED AS RECONDITIONED PART
001 A 164 900 41 01
200 CONTROL UNIT
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
PART IS ONLY OR ALSO SUPPLIED AS RECONDITIONED PART
001 A 164 900 41 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
Zastąpiono przez: A 164 540 46 01
001 A 164 540 44 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
Zastąpiono przez: A 164 540 65 01
001 A 164 540 46 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
001 A 164 540 65 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

FIRST EXHAUST STOCK OF OLD PARTS UP TO IDENT NO.

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
Zastąpiono przez: A 164 440 38 01
001 A 164 540 81 01
200 CONTROL UNIT SAM
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

FIRST EXHAUST STOCK OF OLD PARTS UP TO IDENT NO.

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
001 A 164 440 38 01
200 CONTROL UNIT
SIGNAL ACQUISITION AND ACTUATION MODULE, PASSENGER SIDE

PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE
PART IS ONLY OR ALSO SUPPLIED AS RECONDITIONED PART
001 A 164 900 41 01
230 HEXALOBULAR BOLT
CONTROL UNIT FIXTURE
002 N 000000 002770
300 INFORMATION PANEL
FUSE/RELAY BOX

ONLY VALID WITH EQUIPMENT:
104A/204A/504A
001 A 164 004 99 99
300 INFORMATION SHEET
FUSE/RELAY BOX

OBSERVE WORK INSTRUCTIONS IN WIS WIS-NET#GF40.10-P-0804B#
001 A 164 005 47 99
300 INFORMATION SHEET
FUSE/RELAY BOX

FIRST EXHAUST STOCK OF OLD PARTS UP TO IDENT NO.
001 A 164 006 64 99
300 INFORMATION SHEET
FUSE/RELAY BOX
001 A 164 006 67 99
700 PIN BUSHING HOUSING
RELAY UNIT 10-PIN;F58
001 A 220 545 34 28
710 FEMALE CONTACT
0.75-1.0 MM2 SLK2.8
NB A 013 545 15 26
710 FEMALE CONTACT
1.5-2.5 MM2 SLK2.8
NB A 013 545 16 26
710 ELECTRICAL CABLE
2.5 MM2 SLK

CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED.
SEE WIS FOR REPAIR INSTRUCTIONS.
=================================================================================================
SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION:
A 001 546 99 41 GREEN 0.7 - 2.4 MM2
A 002 546 00 41 RED 2.0 - 4.0 MM2
A 002 546 01 41 BLUE 3.5 - 8.0 MM2
A 002 546 11 41 YELLOW 7.5 - 12.0 MM2
BUTT JOINT:
A 002 546 13 41 0.5 MM2
A 002 546 14 41 0.8 MM2
A 002 546 15 41 1.3 MM2
A 002 546 16 41 2.0 MM2
===================================================================================================
NB A 000 540 40 05
710 ELECTRICAL WIRING HARNESS
4.0 MM2 LSK8

CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED.
SEE WIS FOR REPAIR INSTRUCTIONS.
=================================================================================================
SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION:
A 001 546 99 41 GREEN 0.7 - 2.4 MM2
A 002 546 00 41 RED 2.0 - 4.0 MM2
A 002 546 01 41 BLUE 3.5 - 8.0 MM2
A 002 546 11 41 YELLOW 7.5 - 12.0 MM2
BUTT JOINT:
A 002 546 13 41 0.5 MM2
A 002 546 14 41 0.8 MM2
A 002 546 15 41 1.3 MM2
A 002 546 16 41 2.0 MM2
===================================================================================================
NB A 000 540 57 05
720 PIN BUSHING HOUSING
RELAY UNIT 14-PIN SLK2.8;F58
001 A 220 545 37 28
730 FEMALE CONTACT
0.75-1.0 MM2 SLK2.8
NB A 013 545 15 26
730 FEMALE CONTACT
1.5-2.5 MM2 SLK2.8
NB A 013 545 16 26
730 ELECTRICAL CABLE
2.5 MM2 SLK

CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED.
SEE WIS FOR REPAIR INSTRUCTIONS.
=================================================================================================
SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION:
A 001 546 99 41 GREEN 0.7 - 2.4 MM2
A 002 546 00 41 RED 2.0 - 4.0 MM2
A 002 546 01 41 BLUE 3.5 - 8.0 MM2
A 002 546 11 41 YELLOW 7.5 - 12.0 MM2
BUTT JOINT:
A 002 546 13 41 0.5 MM2
A 002 546 14 41 0.8 MM2
A 002 546 15 41 1.3 MM2
A 002 546 16 41 2.0 MM2
===================================================================================================
NB A 000 540 40 05
740 PIN BUSHING HOUSING
RELAY UNIT 10-PIN;F58
001 A 220 545 68 28
750 FEMALE CONTACT
0.75-1.0 MM2 SLK2.8
NB A 013 545 15 26
750 ELECTRICAL CABLE
2.5 MM2 SLK

CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED.
SEE WIS FOR REPAIR INSTRUCTIONS.
=================================================================================================
SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION:
A 001 546 99 41 GREEN 0.7 - 2.4 MM2
A 002 546 00 41 RED 2.0 - 4.0 MM2
A 002 546 01 41 BLUE 3.5 - 8.0 MM2
A 002 546 11 41 YELLOW 7.5 - 12.0 MM2
BUTT JOINT:
A 002 546 13 41 0.5 MM2
A 002 546 14 41 0.8 MM2
A 002 546 15 41 1.3 MM2
A 002 546 16 41 2.0 MM2
===================================================================================================
NB A 000 540 40 05
760 PIN BUSHING HOUSING
RELAY UNIT 14-PIN SLK2.8;F58
001 A 220 545 99 28
770 FEMALE CONTACT
0.75-1.0 MM2 SLK2.8
NB A 013 545 15 26
770 FEMALE CONTACT
1.5-2.5 MM2 SLK2.8
NB A 013 545 16 26
770 ELECTRICAL CABLE
2.5 MM2 SLK

CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED.
SEE WIS FOR REPAIR INSTRUCTIONS.
=================================================================================================
SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION:
A 001 546 99 41 GREEN 0.7 - 2.4 MM2
A 002 546 00 41 RED 2.0 - 4.0 MM2
A 002 546 01 41 BLUE 3.5 - 8.0 MM2
A 002 546 11 41 YELLOW 7.5 - 12.0 MM2
BUTT JOINT:
A 002 546 13 41 0.5 MM2
A 002 546 14 41 0.8 MM2
A 002 546 15 41 1.3 MM2
A 002 546 16 41 2.0 MM2
===================================================================================================
NB A 000 540 40 05
Aby dowiedzieć się, gdzie kupić przedmiot lub jego odpowiednika, kliknij na numerze katalogowym.