№- | Name | A* | Part number |
---|---|---|---|
010 | HOUSING APPARATUS CASE |
001 | A 211 540 03 24 |
010 | INSTRUMENT-HOUSING | 001 | A 211 540 07 24 |
015 | GROMMET CONTROL MODULE BOX |
001 | A 211 540 04 00 |
017 | BUTTON GROMMET APPARATUS CASE |
001 | A 000 998 41 01 |
018 | COVER HOUSING |
001 | A 211 545 07 03 |
019 | COVER HOUSING |
001 | A 211 546 01 64 |
020 | BLOWER AC BLOWER CONTROL UNIT BOX |
001 | A 210 545 05 95 |
022 | HEXAGON NUT MOUNTING, EQUIPMENT BOX M6 |
004 | N 910112 006001 |
030 | ELECTRICAL BASIC MODULE SIGNAL ACQUISITION + ACTUATION MODULE WITH FRONT FUSE AND RELAY MODULE SAM/SRB N10/1 Replaced by: A 211 545 44 01 |
001 | A 211 545 40 01 |
030 | ELECTRICAL BASIC MODULE SIGNAL ACQUISITION + ACTUATION MODULE WITH FRONT FUSE AND RELAY MODULE SAM/SRB N10/1 Replaced by: A 211 545 72 01 |
001 | A 211 545 44 01 |
030 | ELECTRICAL BASIC MODULE SIGNAL ACQUISITION + ACTUATION MODULE WITH FRONT FUSE AND RELAY MODULE SAM/SRB N10/1 Replaced by: A 211 545 63 01 |
001 | A 211 545 72 01 |
030 | ELECTRICAL BASIC MODULE SIGNAL ACQUISITION + ACTUATION MODULE WITH FRONT FUSE AND RELAY MODULE SAM/SRB N10/1 Replaced by: A 211 545 75 01 |
001 | A 211 545 63 01 |
030 | ELECTRICAL BASIC MODULE SIGNAL ACQUISITION + ACTUATION MODULE WITH FRONT FUSE AND RELAY MODULE SAM/SRB N10/1 Replaced by: A 211 545 78 01 |
001 | A 211 545 75 01 |
030 | ELECTRICAL CENTER SIGNAL ACQUISITION + ACTUATION MODULE WITH FRONT FUSE AND RELAY MODULE SAM/SRB N10/1 |
001 | A 211 545 78 01 |
030 | ELECTRICAL BASIC MODULE SIGNAL ACQUISITION + ACTUATION MODULE WITH FRONT FUSE AND RELAY MODULE SAM/SRB N10/1 PART IS ONLY OR ALSO SUPPLIED AS RECONDITIONED PART |
002 | A 211 545 90 01 |
032 | RELAY CIRCUIT 87 MOTRONIC (M131 DIESEL) I |
001 | A 002 542 13 19 |
032 | RELAY CIRCUIT 87 FW/CHASSIS K |
001 | A 002 542 11 19 |
032 | RELAY STARTER L |
001 | A 002 542 11 19 |
032 | RELAY PUMP CONVENIENCE MANUAL TRANSMISSION (M) |
001 | A 002 542 13 19 |
032 | RELAY TERMINAL 15 N |
001 | A 002 542 26 19 |
032 | RELAY FANFARE HORNS O |
001 | A 002 542 11 19 |
032 | RELAY CIRCUIT 15R P |
001 | A 002 542 26 19 |
032 | RELAY SECONDARY AIR INJ. PUMP OR FAN OIL COOLER R |
001 | A 002 542 13 19 |
032 | RELAY SLOT S, AIRMATIC K67 |
001 | A 002 542 23 19 |
032 | RELAY CIRCUIT 15R K41/1 |
001 | A 002 542 12 19 |
032 | RELAY CIRCUIT 15R K41/1 |
002 | A 002 542 12 19 |
034 | FUSE LINK 5A Replaced by: N 000000 004202 |
NB | N 072581 000302 |
034 | FUSE LINK C-5 |
NB | N 000000 004202 |
034 | FUSE LINK 7.5A |
NB | N 072581 000303 |
034 | FUSE LINK 10A Replaced by: N 000000 004204 |
NB | N 072581 000304 |
034 | FUSE LINK C-10 |
NB | N 000000 004204 |
034 | FUSE LINK 15A |
NB | N 072581 000305 |
034 | FUSE LINK 20A Replaced by: N 000000 004206 |
NB | N 072581 000306 |
034 | FUSE LINK C-20 |
NB | N 000000 004206 |
034 | FUSE LINK 25A Replaced by: N 000000 004207 |
NB | N 072581 000307 |
034 | FUSE LINK C-25 |
NB | N 000000 004207 |
034 | FUSE LINK 30A Replaced by: N 000000 004208 |
NB | N 072581 000308 |
034 | FUSE LINK C-30 |
NB | N 000000 004208 |
034 | FUSE LINK 40A |
NB | N 910153 000000 |
034 | FUSE LINK 40A MAXI Replaced by: N 000000 004215 |
NB | N 000000 000696 |
034 | FUSE LINK E-40 |
NB | N 000000 004215 |
034 | FUSE LINK CONTROL MODULE SAM/SRB FRONT, GREEN E-40 |
001 | N 000000 004215 |
040 | BOLT MOUNTING, ELECTRICAL CENTER 4 X 20 MM |
002 | A 001 984 59 29 |
060 | COVER APPARATUS CASE |
001 | A 211 540 01 82 |
060 | COVER APPARATUS CASE |
001 | A 211 540 04 82 |
070 | BRACKET APPARATUS CASE |
001 | A 211 545 80 40 |
075 | HEXAGON NUT BRACKET MOUNTING M6 |
004 | N 910112 006001 |
095 | BALL PIN ELECTRONIC CONTROL UNIT MOUNTING |
004 | A 000 993 08 60 |
110 | CONTROL UNIT ESP ELECTRONIC STABILITY PROGRAM (ESP) Replaced by: A 211 540 67 45 |
001 | A 211 540 60 45 |
110 | CONTROL UNIT ELECTRONIC STABILITY PROGRAM (ESP) ESP PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE SUCCESSOR AS OF MY 807 IS IN DG 42 TU 060 |
001 | A 211 540 67 45 |
110 | CONTROL UNIT ESP ELECTRONIC STABILITY PROGRAM WITH SPEED-SENSITIVE POWER STEERING Replaced by: A 211 540 66 45 |
001 | A 211 540 59 45 |
110 | CONTROL UNIT ELECTRONIC STABILITY PROGRAM WITH SPEED-SENSITIVE POWER STEERING ESP PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE SUCCESSOR AS OF MY 807 IS IN DG 42 TU 060 |
001 | A 211 540 66 45 |
110 | CONTROL UNIT ESP ELECTRONIC STABILITY PROGRAM (ESP) Replaced by: A 211 540 68 45 |
001 | A 211 540 58 45 |
110 | CONTROL UNIT ELECTRONIC STABILITY PROGRAM (ESP) ESP PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE |
001 | A 211 540 68 45 |
110 | CONTROL UNIT ELECTRONIC STABILITY PROGRAM (ESP) ESP PART MUST BE CHECKED AFTER INSTALLATION FOR CURRENT FLASHWARE SUCCESSOR AS OF MY 807 IS IN DG 42 TU 060 |
001 | A 211 540 68 45 |
120 | BOLT CONTROL UNIT FIXTURE M5X14 |
002 | A 140 990 06 36 |
200 | RELAY HIGH-CURRENT RELAY, IN ENGINE COMP. RIGHT BOLTED TO WHEELHOUSE (2ND BATT.) Replaced by: A 002 542 47 19 |
001 | A 002 542 64 19 |
200 | RELAY HIGH-CURRENT RELAY, IN ENGINE COMP. RIGHT BOLTED TO WHEELHOUSE (2ND BATT.) 12V 150A |
001 | A 002 542 47 19 |
210 | HEXAGON NUT FASTENING HIGH-CURRENT RELAY M6 |
002 | N 910112 006001 |
500 | PIN BUSHING HOUSING CONTROL MODULE SAM/SRB FRONT 12-PIN MQS;N10/1 |
001 | A 001 545 47 40 |
500 | COVER MQS;PART 1 TO A 001 545 47 40 |
001 | A 000 545 91 03 |
500 | COVER CAP PART 2 TO A 001 545 47 40 |
001 | A 000 545 39 30 |
500 | PLUG HOUSING FRONT SAM/SRB CONTROL MODULE, NEUTRAL 14-PIN MQS;N10/1 |
001 | A 002 540 95 81 |
510 | PIN BUSHING HOUSING CONTROL MODULE SAM/SRB FRONT, BLACK 14-PIN SLK2.8;N10/1 |
001 | A 220 545 37 28 |
510 | HOUSING FRONT SAM/SRB CONTROL MODULE, NEUTRAL 10-PIN;N10/1 |
001 | A 039 545 63 28 |
510 | HOUSING CONTROL MODULE SAM/SRB FRONT, BLUE 14-PIN SLK2.8;N10/1 |
001 | A 039 545 61 28 |
510 | PIN BUSHING HOUSING CONTROL MODULE SAM/SRB FRONT, BLACK 10-PIN SLK2.8;N10/1 |
002 | A 220 545 84 28 |
510 | PIN BUSHING HOUSING FRONT SAM/SRB CONTROL MODULE, NEUTRAL 14-PIN SLK2.8;N10/1 |
001 | A 220 545 99 28 |
520 | PLUG HOUSING CONTROL MODULE SAM/SRB FRONT, BLACK 14-PIN MQS;N10/1 |
002 | A 002 540 86 81 |
520 | PIN BUSHING HOUSING CONTROL MODULE SAM/SRB FRONT, VIOLET 4-PIN MQS;N10/1 |
002 | A 039 545 60 28 |
520 | PLUG SOCKET CONTROL MODULE SAM/SRB FRONT, BLUE 14-PIN;N10/1 |
001 | A 002 540 96 81 |
520 | PLUG SOCKET CONTROL MODULE SAM/SRB FRONT, VIOLET 14-PIN;N10/1 |
001 | A 002 540 97 81 |
520 | CLUTCH FRONT SAM/SRB CONTROL MODULE, NEUTRAL 4-PIN MQS; N10/1 S |
001 | A 038 545 12 28 |
520 | CLUTCH FRONT SAM/SRB CONTROL MODULE, NEUTRAL 4-PIN MQS;N10/1 |
002 | A 038 545 12 28 |
520 | PLUG HOUSING CONTROL MODULE SAM/SRB FRONT, BLUE 4-PIN MQS;N10/1 |
002 | A 038 545 73 28 |
520 | SOCKET HOUSING CONTROL MODULE SAM/SRB FRONT, BLACK 4-PIN MQS;N10/1 |
001 | A 037 545 65 28 |
520 | PLUG HOUSING FRONT SAM/SRB CONTROL MODULE, NEUTRAL 4-PIN MQS;N10/1 B |
001 | A 043 545 78 28 |
530 | PLUG HOUSING CONTROL MODULE SAM/SRB FRONT, BLACK 4-PIN MCP2.8;N10/1 |
001 | A 037 545 31 28 |
530 | HOUSING FRONT SAM/SRB CONTROL MODULE, NEUTRAL 6-PIN SLK2.8;N10/1 |
001 | A 037 545 94 28 |
530 | CLUTCH CONTROL MODULE SAM/SRB FRONT, BLUE 4-PIN MCP 2.8;N10/1 |
001 | A 037 545 32 28 |
530 | PLUG HOUSING FRONT SAM/SRB CONTROL MODULE, NEUTRAL 4-PIN MQS;N10/1 |
002 | A 043 545 78 28 |
530 | CLUTCH CONTROL MODULE SAM/SRB FRONT, BLACK 6-PIN MCP2.8;N10/1 |
001 | A 037 545 35 28 |
530 | HOUSING FRONT SAM/SRB CONTROL MODULE, NEUTRAL 4-PIN MCP2.8;I2; N10/1 |
001 | A 037 545 86 28 |
540 | CLUTCH CONTROL MODULE SAM/SRB FRONT 1-PIN JPT;N10/1 |
001 | A 210 545 40 28 |
550 | ELECTRICAL CABLE 0.5 MM2 MQS CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED. SEE WIS FOR REPAIR INSTRUCTIONS. ================================================================================================= SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION: A 001 546 99 41 GREEN 0.7 - 2.4 MM2 A 002 546 00 41 RED 2.0 - 4.0 MM2 A 002 546 01 41 BLUE 3.5 - 8.0 MM2 A 002 546 11 41 YELLOW 7.5 - 12.0 MM2 BUTT JOINT: A 002 546 13 41 0.5 MM2 A 002 546 14 41 0.8 MM2 A 002 546 15 41 1.3 MM2 A 002 546 16 41 2.0 MM2 =================================================================================================== |
NB | A 000 540 23 05 |
560 | CONTACT SPRING 0.22-0.5 MM2 SLK2.8 |
NB | A 013 545 14 26 |
560 | FEMALE CONTACT 0.75-1.0 MM2 SLK2.8 |
NB | A 013 545 15 26 |
560 | FEMALE CONTACT 0.75-1.0 MM2 SLK2.8;114 |
NB | A 013 545 15 26 |
560 | FEMALE CONTACT 1.5-2.5 MM2 SLK2.8 |
NB | A 013 545 16 26 |
560 | FEMALE CONTACT 4.0 MM2 SLK2.8 |
NB | A 011 545 07 26 |
570 | ELECTRICAL CABLE 0.5 MM2 MQS CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED. SEE WIS FOR REPAIR INSTRUCTIONS. ================================================================================================= SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION: A 001 546 99 41 GREEN 0.7 - 2.4 MM2 A 002 546 00 41 RED 2.0 - 4.0 MM2 A 002 546 01 41 BLUE 3.5 - 8.0 MM2 A 002 546 11 41 YELLOW 7.5 - 12.0 MM2 BUTT JOINT: A 002 546 13 41 0.5 MM2 A 002 546 14 41 0.8 MM2 A 002 546 15 41 1.3 MM2 A 002 546 16 41 2.0 MM2 =================================================================================================== |
NB | A 000 540 45 05 |
570 | FEMALE CONTACT 0.25-0.5 MM2 MQS |
NB | A 016 545 41 26 |
570 | ELECTRICAL CABLE 0.75 MM2 MQS CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED. SEE WIS FOR REPAIR INSTRUCTIONS. ================================================================================================= SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION: A 001 546 99 41 GREEN 0.7 - 2.4 MM2 A 002 546 00 41 RED 2.0 - 4.0 MM2 A 002 546 01 41 BLUE 3.5 - 8.0 MM2 A 002 546 11 41 YELLOW 7.5 - 12.0 MM2 BUTT JOINT: A 002 546 13 41 0.5 MM2 A 002 546 14 41 0.8 MM2 A 002 546 15 41 1.3 MM2 A 002 546 16 41 2.0 MM2 =================================================================================================== |
NB | A 000 540 46 05 |
580 | FEMALE CONTACT 0.2-0.35 MM2 MCP2.8 |
NB | A 015 545 04 26 |
580 | FEMALE CONTACT 0.5-1.0 MM2 MCP2.8 |
NB | A 013 545 76 26 |
580 | FEMALE CONTACT 1.5-2.5 MM2 MCP2.8 |
NB | A 013 545 78 26 |
590 | CONTACT SPRING 0.5-1.0 MM2 JPT |
NB | A 011 545 81 26 |
800 | PIN BUSHING HOUSING AUXILIARY BATTERY RELAY 2-PIN MINI MIC;K57/2 |
001 | A 015 545 55 26 |
850 | PIN BUSHING HOUSING CONTROL MODULE ELECTRONIC STABILITY PROGRAM 2-PIN MQS;N47 |
001 | A 029 545 40 28 |
850 | COVER 2-PIN MQS;TO A 029 545 40 28 |
001 | A 000 545 22 46 |
870 | FEMALE CONTACT 0.25-0.5 MM2 MQS |
NB | A 016 545 41 26 |
870 | ELECTRICAL CABLE 0.75 MM2 MQS CONNECTORS MUST ALSO BE ORDERED IN ACC. WITH THE TOTAL CABLE C ROSS-SECTION TO BE CONNECTED. SEE WIS FOR REPAIR INSTRUCTIONS. ================================================================================================= SOLDER CONNECTOR SLEEVES: TOTAL WIRE CROSS-SECTION: A 001 546 99 41 GREEN 0.7 - 2.4 MM2 A 002 546 00 41 RED 2.0 - 4.0 MM2 A 002 546 01 41 BLUE 3.5 - 8.0 MM2 A 002 546 11 41 YELLOW 7.5 - 12.0 MM2 BUTT JOINT: A 002 546 13 41 0.5 MM2 A 002 546 14 41 0.8 MM2 A 002 546 15 41 1.3 MM2 A 002 546 16 41 2.0 MM2 =================================================================================================== |
NB | A 000 540 46 05 |
880 | CONTACT SPRING 0.35-0.5 MM2 MINI MIC |
NB | A 018 545 77 26 |