№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
central wiring set individual parts area: wiring harness for interior dashboard |
||||||
1 | central wiring set | |||||
2 | grommet | 1 | 1J0 971 915 C | - | ||
5 | bracket for relay bracket | 1 | 18D 907 371 | - | ||
8 | flat contact housing possible single wire: |
X X X |
8E0 971 833 | - | ||
9 | flat contact housing possible single wire: 0,5 0,5 |
0,5 0,5 |
X X X |
1C0 973 119 B | - | |
10 | flat contact housing possible single wire: 1,0 1,0 2,5 |
1,0 1,0 2,5 |
X X X X |
893 971 633 | - | |
11 | flat contact housing possible single wire: GEGENSTUECK: |
1 X X X |
3B0 972 722 | - | ||
12 | flat contact housing connection piece switch for driving headlights possible single wire: 1,0 2,5 |
1,0 2,5 |
1 X X |
1J0 972 999 | 2 | |
13 | flat connector housing with contact locking mechanism to use for: |
1 | 1J0 937 743 | - | ||
14 | flat connector housing with contact locking mechanism to use for: |
1 | 1J0 937 743 | - | ||
15 | flat connector housing with contact locking mechanism to use for: |
1 | 1J0 937 743 | - | ||
16 | fuse holder | 1 | 6Q0 941 828 B | - | ||
17 | cable tie with holder for weld pin: |
X | 6Q0 971 838 C | - | ||
20 | flat contact housing airbag possible single wire: |
1 X |
6X0 972 773 | - | ||
21 | flat contact housing with contact locking mechanism use if required: to use for: |
1 1 |
1J0 937 713 | - | ||
21 | flat contact housing with contact locking mechanism use if required: to use for: |
1 1 |
1J0 937 714 | - | ||
22 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
1J0 973 119 | - | ||
23 | flat contact housing with contact locking mechanism possible single wire: 0,5 |
0,5 |
X X |
4B0 972 575 | - | |
27 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
4B0 972 623 | - | ||
28 | flat contact housing with contact locking mechanism possible single wire: |
1 X X X X |
1J0 973 722 | 3 | ||
31 | flat contact housing possible single wire: GEGENSTUECK: |
1 X X X |
3B0 972 722 | - | ||
32 | flat contact housing possible single wire: 1,0 1,0 2,5 2,5 |
1,0 1,0 2,5 2,5 |
1 X X X X |
1J0 972 704 | 6 | |
36 | bracket protective cover for contact: |
X X X X |
6H0 971 921 C | - | ||
39 | cable holder hole/sheet metal thickness: |
X | 6Q0 971 848 F | - | ||
41 | cable holder hole/sheet metal thickness: |
X | 6Q0 971 848 L | - | ||
45 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
1J0 972 923 | - | ||
47 | flat contact housing with contact locking mechanism possible single wire: 0,5 0,5 |
0,5 0,5 |
1 X X |
8E0 972 112 | - | |
48 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
8E0 972 416 | - | ||
50 | flat contact housing possible single wire: 1,0 1,0 |
1,0 1,0 |
1 X X |
1H0 972 702 A | - | |
56/57 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
1J0 972 923 | - | ||
59 | grommet wiring set for side marker light |
1 | 3B0 971 913 B | - | ||
60-63 | flat contact housing with contact locking mechanism possible single wire: matching contact housing: for ultrasound sensor |
1 X X |
4F0 973 703 | - | ||
60-63 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
3B0 972 703 | - | ||
65 | flat contact housing with cap possible single wire: 0,5 0,5 |
0,5 0,5 |
1 X X |
1J0 972 977 D | - | |
67 | flat contact housing rework if necessary |
1 | 6R0 971 975 A | - | ||
68 | flat contact housing with contact locking mechanism possible single wire: |
1 | 4B0 971 832 | - | ||
69 | flat contact housing steering col. combi switch possible single wire: |
1 X X X |
6Q0 971 975 C | - | ||
69 | cable guide | 1 | 1J0 971 821 A | - | ||
- | flat contact housing KESSY B |
1 | 5C0 971 974 | - | ||
- | flat contact housing KESSY A |
1 | 5C0 971 975 | - | ||
70 | cable tie with terminal socket with side cable guide for bridge strength: toothed quadrant |
X | 1Y0 971 838 | - | ||
71 | flat contact housing possible single wire: connection piece for diagnostic plug |
1 X |
3A0 972 695 | - | ||
72 | flat contact housing possible single wire: 1,0 1,0 |
1,0 1,0 |
1 X X X |
3B0 972 706 | - | |
73 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
1J0 973 119 | - | ||
74/76 | flat contact housing possible single wire: 0,5 0,5 |
0,5 0,5 |
X X X |
4D0 971 636 | - | |
79 | flat contact housing possible single wire: cigarette lighter |
1 X |
1J0 919 321 | - | ||
85 | flat contact housing with contact locking mechanism possible single wire: 1,0 2,5 6,0 |
1,0 2,5 6,0 |
1 X X X |
1J0 972 775 | - | |
86 | flat contact housing with contact locking mechanism possible single wire: matching contact housing: |
1 X X |
6Q0 972 777 | - | ||
92 | flat contact housing possible single wire: 1,0 1,0 2,5 2,5 |
1,0 1,0 2,5 2,5 |
1 X X X X |
1J0 972 704 | 6 | |
93 | flat contact housing possible single wire: |
X X X X |
1J0 959 869 | - | ||
99 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
1J0 973 119 | - | ||
100 | flat contact housing with contact locking mechanism use if required: to use for: |
1 1 |
1J0 937 713 A | - | ||
100 | flat contact housing with contact locking mechanism use if required: to use for: |
1 1 |
1J0 937 714 A | - | ||
101 | flat contact housing airbag possible single wire: |
1 X |
6X0 972 773 | - | ||
106 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
1J0 972 923 | - | ||
107 | flat contact housing with contact locking mechanism possible single wire: 1,0 1,0 |
1,0 1,0 |
1 X X |
1J0 973 704 | 3 | |
110 | cable guide | 1 | 1J0 971 615 S | - | ||
113 | flat contact housing possible single wire: |
1 | 1K0 919 231 | - | ||
114 | cable holder | X | 180 971 615 B | - | ||
116 | flat contact housing with contact locking mechanism possible single wire: |
1 X X |
1J0 972 923 | - | ||
119 | flat contact housing with contact locking mechanism possible single wire: |
1 | 3B7 035 447 | - | ||
120 | flat contact housing radio possible single wire: |
1 X X X X |
357 035 447 A | - | ||
120 | flat contact housing with contact locking mechanism |
1 | 8X0 035 447 | - | ||
120 | flat contact housing with contact locking mechanism |
1 | 8X0 035 447 A | - | ||
121 | flat contact housing with additional contact lock and additional connector housing mountings possible single wire: |
1 X X X |
3B7 035 444 | - | ||
- | cable holder | X | 6Q0 971 848 P | - | ||
- | cable holder only for: hole/sheet metal thickness: clip spacing: |
X | 1H0 971 848 AJ | - | ||
- | relay plate possible single wire: 1,0 1,0 1,0 1,0 2,5 2,5 |
1,0 1,0 1,0 1,0 2,5 2,5 |
X X X X X X X |
443 937 527 | - | |
- | relay plate | 1 | 3C0 973 721 | - | ||
- | protective cap | 1 | 1J0 971 921 | - | ||
- | flat connector housing with contact locking mechanism to use for: |
1 | 1J0 937 743 B | - | ||
- | flat connector housing control unit for airbag locking mechanism PR-4X1
RAL 6032 |
PR-4X1 RAL 6032 |
1 | 6R0 973 206 | - | |
- | flat connector housing control unit for airbag locking mechanism PR-4X0
RAL 5023 |
PR-4X0 RAL 5023 |
1 | 6R0 973 206 B | - | |
- | flat connector housing control unit for airbag locking mechanism PR-4X0
RAL 5023 |
PR-4X0 RAL 5023 |
1 | 6R0 973 206 A | - | |
- | flat contact housing with contact locking mechanism possible single wire: 1,0 1,0 4,0 |
1,0 1,0 4,0 |
X X X X |
8Z0 972 701 | - | |
- | flat connector housing for contact: contact switch |
X X X X |
431 971 995 | - | ||
- | flat contact housing possible single wire: matching contact housing: TASTER STARTER 0,5 0,5 |
0,5 0,5 |
1 X X |
8K0 973 754 | - | |
- | flat contact housing possible single wire: 0,5 0,5 |
0,5 0,5 |
1 X X |
8L0 971 883 | - | |
- | flat contact housing with contact locking mechanism possible single wire: |
1 X X X |
1K0 937 722 D | - | ||
- | fuse holder for contact: |
1 X X |
8A0 937 530 | - | ||
- | flat contact housing with contact locking mechanism possible single wire: |
1 X X X |
5N0 937 722 | - | ||
- | flat contact housing with contact locking mechanism onboard supply control unit |
1 | 6R0 937 700 | - | ||
- | flat contact housing with contact locking mechanism onboard supply control unit |
1 | 6R0 937 700 A | - | ||
- | adapter | 1 | 7M0 937 632 B | - | ||
- | bracket for connector housing | 1 | 1J0 937 545 G | - | ||
- | flat contact housing | 1 | 4H0 972 133 | - | ||
- | flat contact housing with contact locking mechanism also to be used for: possible single wire: counterpart to: sun sensor |
1 | 8E0 971 832 | - | ||
- | flat contact housing with contact locking mechanism to use for: control unit for seat heating |
1 | 1J0 937 733 | - | ||
- | flat contact housing possible single wire: 1,0 1,0 2,5 |
1,0 1,0 2,5 |
1 X X X |
893 971 636 | - | |
- | flat contact housing radio possible single wire: |
1 | 4A0 972 643 | - | ||
- | cable guide - upper part | 1 | 18D 971 865 | - | ||
- | cable guide - lower part | 1 | 18D 971 866 | - | ||
- | cable holder PR-4I2
|
PR-4I2 | 1 | 18D 971 930 | - | |
- | bungs PR-7X0
|
PR-7X0 | 1 | 18D 971 908 | - | |
- | grommet | 2 | 18D 971 841 | - | ||
- | cable holder PR-T0K
|
PR-T0K | 1 | 180 971 845 D | - |