Control unit (bcm) for conv. s..

ETKA / Volkswagen / Golf / (2012 - 2013) / 9 / 937-057
Name Ext. inf. A* Use of Part number A
control unit (bcm) for
conv. system & ob power supply
diagnosis interface for
data bus (gateway)
D - 07.11.2011>> - 21.05.2012*
PR-5D2,5D3
PR-5D2,5D3
control unit (bcm) for
conv. system & ob power supply
D - 07.11.2011>> - 21.05.2012*
------------------------------
PR-5D2,5D3
PR-5D2,5D3
(1) control unit (bcm) for
conv. system & ob power supply

also to be used for:
PR-8BK,8BG+
7R3,7R4+8K0,
8K1,8K3,8K8
PR-8BK,8BG+
7R3,7R4+8K0,
8K1,8K3,8K8
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL0
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL0
1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL0
PR-9AA+8TA+
8SA,8SD+KL0
1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL1
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL1
1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL1
PR-9AA+8TA+
8SA,8SD+KL1
1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL0
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SA,8SD+KL0
PR-9AK,9AM,
9AP,KH6+8TA+
8SA,8SD+KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL1
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL1
1K0 937 087 T Z 0C -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL1
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL1
1K0 937 087 T Z 0C -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK+KL0
PR-9AA+8TA+
8SK+KL0
1K0 937 087 T Z 14 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK+KL1
PR-9AA+8TA+
8SK+KL1
1K0 937 087 T Z 16 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL0
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL0
1K0 937 087 T Z 18 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL1
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL1
1K0 937 087 T Z 1A -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-8BK,8BG+
7R3,7R4+8K0,
8K1,8K3,8K8+
D77
PR-8BK,8BG+
7R3,7R4+8K0,
8K1,8K3,8K8+
D77
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL0
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL0
1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL0
PR-9AA+8TA+
8SA,8SD+KL0
1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL1
PR-9AA+8TC,
8TD+8SA,8SD,
8SK+KL1
1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL1
PR-9AA+8TA+
8SA,8SD+KL1
1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL0
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SA,8SD+KL0
PR-9AK,9AM,
9AP,KH6+8TA+
8SA,8SD+KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL1
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK+KL1
1K0 937 087 T Z 0H -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SA,8SD+KL1
PR-9AK,9AM,
9AP,KH6+8TA+
8SA,8SD+KL1
1K0 937 087 T Z 0H -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK+KL0
PR-9AA+8TA+
8SK+KL0
1K0 937 087 T Z 15 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK+KL1
PR-9AA+8TA+
8SK+KL1
1K0 937 087 T Z 17 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL0
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL0
1K0 937 087 T Z 19 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL1
PR-9AK,9AM,
9AP,KH6+8TA+
8SK+KL1
1K0 937 087 T Z 1B -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8BI,8EI+8K1,
8K3
PR-7R3,7R4+
8BI,8EI+8K1,
8K3
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL0
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL0
1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL0
PR-9AA+8TA+
8SA,8SD+KL0
1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL1
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL1
1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL1
PR-9AA+8TA+
8SA,8SD+KL1
1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL0
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL0
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL1
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL1
1K0 937 087 T Z 0C -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL1
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL1
1K0 937 087 T Z 0C -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK,8SP+KL0
PR-9AA+8TA+
8SK,8SP+KL0
1K0 937 087 T Z 0W -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK,8SP+KL1
PR-9AA+8TA+
8SK,8SP+KL1
1K0 937 087 T Z 0Y -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL0
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL0
1K0 937 087 T Z 10 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL1
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL1
1K0 937 087 T Z 12 -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8BI,8EI+8K1,
8K3+D77
PR-7R3,7R4+
8BI,8EI+8K1,
8K3+D77
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL0
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL0
1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL0
PR-9AA+8TA+
8SA,8SD+KL0
1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL1
PR-9AA+8TC,
8TD+8SA,8SD,
8SK,8SP+KL1
1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SA,8SD+KL1
PR-9AA+8TA+
8SA,8SD+KL1
1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL0
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL0
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL1
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SA,8SD,
8SK,8SP+KL1
1K0 937 087 T Z 0H -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL1
PR-9AK,9AM,
9AP,KH6+8TA,
8SA,8SD+KL1
1K0 937 087 T Z 0H -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK,8SP+KL0
PR-9AA+8TA+
8SK,8SP+KL0
1K0 937 087 T Z 0X -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA+
8SK,8SP+KL1
PR-9AA+8TA+
8SK,8SP+KL1
1K0 937 087 T Z 0Z -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL0
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL0
1K0 937 087 T Z 11 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL1
PR-9AK,9AM,
9AP,KH6+8TA+
8SK,8SP+KL1
1K0 937 087 T Z 13 -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
PR-9AA+8TC,
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SP+KL0
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SP+KL0
1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K1,
8K3,8K0,8K8+
8TC,8TD+8SP+
KL1
PR-9AA+8K1,
8K3,8K0,8K8+
8TC,8TD+8SP+
KL1
1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL0
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL1
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL1
1K0 937 087 T Z 0C -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
1K0 937 087 T Z 0C -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8+D77
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8+D77
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TC,
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
PR-9AA+8TC,
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SP+KL0
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SP+KL0
1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K1,
8K3,8K0,8K8+
8TC,8TD+8SP+
KL1
PR-9AA+8K1,
8K3,8K0,8K8+
8TC,8TD+8SP+
KL1
1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
PR-9AA+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL0
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL1
PR-9AK,9AM,
9AP,KH6+8TC
8TD+8SP+8K1,
8K3,8K0,8K8+
KL1
1K0 937 087 T Z 0H -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
PR-9AK,9AM,
9AP,KH6+8TA,
8TC,8TD+8K0,
8K8+8SK,8SA,
8SD+KL1
1K0 937 087 T Z 0H -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8ES,8EB+8K0,
8K4,8K8,8K9+
8SA,8SD
PR-7R3,7R4+
8ES,8EB+8K0,
8K4,8K8,8K9+
8SA,8SD
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL0
PR-9AA+KL0 1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL1
PR-9AA+KL1 1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL0
PR-9AK,9AM,
9AP,KH6+KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL1
PR-9AK,9AM,
9AP,KH6+KL1
1K0 937 087 T Z 0C -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8ES,8EB+8K0,
8K4,8K8,8K9+
8SA,8SD+D77
PR-7R3,7R4+
8ES,8EB+8K0,
8K4,8K8,8K9+
8SA,8SD+D77
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL0
PR-9AA+KL0 1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL1
PR-9AA+KL1 1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL0
PR-9AK,9AM,
9AP,KH6+KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL1
PR-9AK,9AM,
9AP,KH6+KL1
1K0 937 087 T Z 0H -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8JF+8K0,8K2,
8K8,9C9+8SA,
8SD
PR-7R3,7R4+
8JF+8K0,8K2,
8K8,9C9+8SA,
8SD
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL0
PR-9AA+KL0 1K0 937 087 T Z 06 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL1
PR-9AA+KL1 1K0 937 087 T Z 08 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL0
PR-9AK,9AM,
9AP,KH6+KL0
1K0 937 087 T Z 0A -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL1
PR-9AK,9AM,
9AP,KH6+KL1
1K0 937 087 T Z 0C -
(1) control unit (bcm) for
conv. system & ob power supply
PR-7R3,7R4+
8JF+8K0,8K2,
8K8,9C9+8SA,
8SD+D77
PR-7R3,7R4+
8JF+8K0,8K2,
8K8,9C9+8SA,
8SD+D77
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL0
PR-9AA+KL0 1K0 937 087 T Z 0E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+KL1
PR-9AA+KL1 1K0 937 087 T Z 0F -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL0
PR-9AK,9AM,
9AP,KH6+KL0
1K0 937 087 T Z 0G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+KL1
PR-9AK,9AM,
9AP,KH6+KL1
1K0 937 087 T Z 0H -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8+8TA+
8SP
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8+8TA+
8SP
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K1,
8K3+KL0
PR-9AA+8K1,
8K3+KL0
1K0 937 087 T Z 0W -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K1,
8K3+KL1
PR-9AA+8K1,
8K3+KL1
1K0 937 087 T Z 0Y -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL0
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL0
1K0 937 087 T Z 10 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL1
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL1
1K0 937 087 T Z 12 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K0,
8K8+KL0
PR-9AA+8K0,
8K8+KL0
1K0 937 087 T Z 1E -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K0,
8K8+KL1
PR-9AA+8K0,
8K8+KL1
1K0 937 087 T Z 1G -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL0
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL0
1K0 937 087 T Z 1J -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL1
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL1
1K0 937 087 T Z 1L -
(1) control unit (bcm) for
conv. system & ob power supply
also to be used for:
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8+8TA+
8SP+D77
PR-7R3,7R4+
8BV,8ET,8JW,
8JX+8K0,8K1,
8K3,8K8+8TA+
8SP+D77
1 1K0 937 087 T  -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K1,
8K3+KL0
PR-9AA+8K1,
8K3+KL0
1K0 937 087 T Z 0X -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K1,
8K3+KL1
PR-9AA+8K1,
8K3+KL1
1K0 937 087 T Z 0Z -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL0
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL0
1K0 937 087 T Z 11 -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL1
PR-9AK,9AM,
9AP,KH6+8K1,
8K3+KL1
1K0 937 087 T Z 13 -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K0,
8K8+KL0
PR-9AA+8K0,
8K8+KL0
1K0 937 087 T Z 1F -
control unit (bcm) for
conv. system & ob power supply
PR-9AA+8K0,
8K8+KL1
PR-9AA+8K0,
8K8+KL1
1K0 937 087 T Z 1H -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL0
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL0
1K0 937 087 T Z 1K -
control unit (bcm) for
conv. system & ob power supply
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL1
PR-9AK,9AM,
9AP,KH6+8K0,
8K8+KL1
1K0 937 087 T Z 1M -
diagnosis interface for
data bus (gateway)
D - 07.11.2011>> - 21.05.2012*
PR-5D2,5D3
PR-5D2,5D3
(3) diagnosis interface for
data bus (gateway)
PR-7L3
PR-7L3 1 7N0 907 530 M  -
diagnosis interface for
data bus (gateway)
7N0 907 530 M Z 00 -
(3) diagnosis interface for
data bus (gateway)
to use for:
PR-7L6
PR-7L6 1 7N0 907 530 Q  -
diagnosis interface for
data bus (gateway)
7N0 907 530 Q Z 00 -
fasteners
D - 07.11.2011>> - 21.05.2012*
PR-5D2,5D3
PR-5D2,5D3
5 bracket
1 1K1 941 397 G  -
(5) bracket
1 1K2 941 397 C  -
7 speed nut
2 N  903 425 04  -
8 hex collared bolt
2 N  910 799 01  -
* In the column 'A' indicates the number that is used in the selected vehicle.
To find out where to buy the item or equivalent, click on the part number.