№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
wiring harness: front right 2E,ADY
|
2E,ADY | |||||
wiring harness: front right F >> 50-S-000 718 2E
|
2E | |||||
1 | wiring harness: front right | 1 | 535 971 072 DN | - | ||
(1) | wiring harness: front right automatic
|
automatic | 1 | 535 971 072 DP | - | |
(1) | wiring harness: front right | 1 | 536 971 072 BP | - | ||
1 | wiring harness: front right | 1 | 535 971 072 EC | - | ||
(1) | wiring harness: front right automatic
|
automatic | 1 | 535 971 072 ED | - | |
(1) | wiring harness: front right | 1 | 536 971 072 CQ | - | ||
(1) | wiring harness: front right automatic
|
automatic | 1 | 536 971 072 CR | - | |
wiring harness: front right F 50-S-000 719>> ADY
|
ADY | |||||
(1) | wiring harness: front right | 1 | 535 971 072 FA | - | ||
(1) | wiring harness: front right automatic
|
automatic | 1 | 535 971 072 FB | - | |
(1) | wiring harness: front right | 1 | 536 971 072 DG | - | ||
(1) | wiring harness: front right automatic
|
automatic | 1 | 536 971 072 DH | - | |
individual parts | ||||||
2 | cable ties | 1 | N 020 902 2 | - | ||
- | insulating tape | 1 | N 103 113 03 | - | ||
4 | corrugated pipe | * | N 905 930 01 | - | ||
(4) | corrugated pipe | * | 1H0 971 820 E | - | ||
- | insulating tape | 1 | N 103 113 04 | - | ||
4 | corrugated pipe in coils of 5m 'order unit 5' |
* | N 907 736 01 | - | ||
(4) | corrugated pipe in coils of 5m 'order unit 5' |
* | N 906 355 17 | - | ||
5 | flat contact housing with contact locking mechanism slot: |
1 | 357 903 968 | - | ||
6 | grommet | 1 | 443 906 102 B | - | ||
7 | flat contact housing connection piece ground connector hall sensor |
1 | 701 906 231 | - | ||
8 | flat contact housing connection piece knock sensor air flow meter ADY |
ADY |
X 1 1 |
443 906 233 | - | |
10 | flat contact housing connection piece air flow meter 2E
|
2E | 1 | 025 906 235 B | 1 | |
11 | flat contact housing with gasket connection piece exhaust recirculation valve temperature sensor ADY |
ADY |
X 1 1 |
037 906 240 | - | |
12 | flat contact housing with gasket connection piece control unit 2E
|
2E | 1 | 1H0 906 370 H | - | |
(12) | flat contact housing with gasket connection piece control unit F >> 50-S-000 718 ADY |
ADY |
1 |
1H0 906 370 J | - | |
(12) | flat contact housing with gasket connection piece control unit F 50-S-000 719>> ADY |
ADY |
1 |
1H0 906 365 | - | |
(12) | flat contact housing with gasket connection piece control unit F 50-S-000 719>> ADY |
ADY |
1 |
1H0 906 370 K | - | |
13 | seal | 1 | 1H0 906 375 | - | ||
15 | grommet 2E
|
2E | 1 | 357 906 376 G | - | |
(15) | protective cap ADY
|
ADY | 1 | 357 906 376 E | - | |
16 | bracket protective cover | 1 | 357 906 732 B | - | ||
17 | flat contact housing slot: |
1 | 357 915 971 C | - | ||
18 | grommet | 1 | 853 945 521 | - | ||
18 | protective cap | 1 | 893 945 521 | - | ||
19 | flat contact housing with contact locking mechanism slot: |
1 | 357 955 968 A | - | ||
(21) | clip connection piece line starter |
1 | 1H0 971 615 P | - | ||
22 | corrugated pipe in coils of 5m 'order unit 5' |
* | N 906 355 17 | - | ||
23 | grommet | 1 | 1H0 971 840 | - | ||
24 | cable holder | 1 | 4B0 971 848 | - | ||
24 | cable holder | 1 | 1H0 971 848 F | - | ||
(24) | cable holder | 1 | 1H0 971 848 Q | - | ||
25 | flat contact housing connection piece oil pressure sender |
1 | 111 971 921 B | - | ||
27 | clamp connection piece line air flow meter |
2 | 1H0 971 939 | - | ||
29 | flat contact housing with contact locking mechanism slot: |
1 | 357 971 967 | - | ||
30 | flat contact housing with contact locking mechanism slot: |
1 | 357 971 967 A | - | ||
32 | flat contact housing connection piece wiring set for dash panel |
1 | 191 972 701 | - | ||
33 | flat contact housing with contact locking mechanism connection piece for diagnostic plug |
1 | 1J0 972 923 | - | ||
33 | flat contact housing connection piece for diagnostic plug |
1 | 1J0 972 702 | - | ||
33 | flat contact housing connection piece for diagnostic plug |
1 | 191 972 702 | - | ||
34 | flat connector housing connection piece instrument housing ADY |
ADY |
X 1 1 |
191 972 711 | - | |
35 | flat connector housing coupling element wiring harness for electric fan |
1 | 191 972 712 | 1 | ||
(35) | flat contact housing automatic
|
automatic | 1 | 191 972 724 | 1 | |
37 | single wiring seal for wire cross section: |
X | 357 972 740 D | - | ||
38 | single wiring seal for wire cross section: |
X | 357 972 741 | - | ||
39 | single wiring seal for wire cross section: |
X | 357 972 741 A | 2 | ||
40 | single wiring seal for wire cross section: |
1 | 357 972 742 C | - | ||
41 | flat contact housing with gasket connection piece terminal |
1 | 357 972 751 | - | ||
(41) | flat contact housing automatic
|
automatic | 1 | 1J0 972 752 | - | |
(41) | flat contact housing automatic
|
automatic | 1 | 191 972 752 | - | |
(41) | flat contact housing connection piece for vehicles with anti-theft alarm system and imobiliser also use: F 50-R-003 961>> |
X 1 |
1J0 972 752 | - | ||
(41) | flat contact housing connection piece for vehicles with anti-theft alarm system and imobiliser also use: F 50-R-003 961>> |
X 1 |
191 972 752 | - | ||
42 | flat contact housing with gasket connection piece external temperature sensor switch for reversing light |
X 1 1 |
357 972 752 | 3 | ||
43 | flat contact housing connection piece transformer distance sensor speed sensor ADY |
ADY |
X 1 1 1 |
357 972 753 | - | |
44 | flat contact housing connection piece lambda probe 2E
|
2E | 1 | 357 972 754 J | - | |
(44) | flat contact housing connection piece lambda probe ADY
|
ADY | 1 | 3A0 973 204 | - | |
45 | flat contact housing connection piece wiper motor |
1 | 357 972 755 | - | ||
46 | flat contact housing with gasket connection piece starter |
1 | 357 972 771 | - | ||
47 | bungs | X | 3C0 972 841 | 2 | ||
47 | bungs | X | 4B0 972 840 | - | ||
47 | bungs | X | 357 972 840 | - | ||
48 | flat contact housing with gasket connection piece wiring set for engine |
1 | 1H0 973 103 | - |