№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
wiring set for dash panel | ||||||
wiring set for dash panel | ||||||
1 | wiring set for dash panel when ordering, provide vehicle identification number. F >> 3U-39047 828 |
1 | 3U1 971 315 ND | - | ||
(1) | wiring set for dash panel when ordering, provide vehicle identification number. F 3U-49047 829>> F 3U-5A300 130>> F 3U-7B299 922>> |
1 | 3U1 971 315 NE | - | ||
(1) | wiring set for dash panel when ordering, provide vehicle identification number. F >> 3U-39047 828 |
1 | 3U2 971 315 ND | - | ||
(1) | wiring set for dash panel when ordering, provide vehicle identification number. F 3U-49047 829>> F 3U-5A300 130>> F 3U-7B299 922>> |
1 | 3U2 971 315 NE | - | ||
individual parts | ||||||
2 | flat contact housing with contact locking mechanism trim for central electrics wiring harness for series resistance use if required: possible single wire: |
1 1 X X |
1J0 937 713 | - | ||
3 | flat contact housing with contact locking mechanism trim for central electrics use if required: possible single wire: |
1 1 X X |
1J0 937 713 A | - | ||
4 | flat contact housing with contact locking mechanism trim for central electrics use if required: possible single wire: |
X 1 X X |
1J0 937 713 B | - | ||
5 | flat connector housing with contact locking mechanism harness for engine compartment possible single wire: |
1 X X X X |
1J0 937 743 | - | ||
6 | flat connector housing with contact locking mechanism harness for engine compartment possible single wire: |
1 X X X X |
1J0 937 743 A | - | ||
7 | flat contact housing with contact locking mechanism harness for engine compartment possible single wire: |
1 X X X |
1J0 937 733 | - | ||
8 | flat contact housing with contact locking mechanism harness for engine compartment possible single wire: 0,5 |
0,5 |
2 X |
4B0 972 575 | - | |
9 | flat contact housing with contact locking mechanism harness for engine compartment use if required: possible single wire: |
2 X X X |
1J0 937 724 B | - | ||
10 | flat contact housing with contact locking mechanism harness for engine compartment possible single wire: 0,5 |
0,5 |
X X |
4B0 972 585 | - | |
11 | flat contact housing with contact locking mechanism harness for engine compartment use if required: possible single wire: |
1 1 X X X X |
1J0 937 714 A | - | ||
12 | flat connector housing with contact locking mechanism harness for engine compartment possible single wire: 1,0 1,0 1,0 1,0 2,5 |
1,0 1,0 1,0 1,0 2,5 |
1 X X X X X |
1J0 937 743 D | - | |
13 | flat contact housing with contact locking mechanism wiring harness for interior possible single wire: |
1 X X X X |
1J0 937 713 D | - | ||
14 | flat contact housing with contact locking mechanism wiring harness for interior possible single wire: |
2 X X X X |
1J0 937 733 A | - | ||
15 | flat contact housing with contact locking mechanism wiring harness for interior possible single wire: |
1 X X X X |
1J0 937 733 B | - | ||
16 | flat contact housing with contact locking mechanism wiring harness for interior possible single wire: 0,5 |
0,5 |
X X |
4B0 972 585 | - | |
17 | flat contact housing with contact locking mechanism wiring harness for interior use if required: possible single wire: |
1 1 X X X X |
1J0 937 714 | - | ||
17A | flat contact housing with contact locking mechanism wiring harness for interior use if required: possible single wire: |
1 1 X X |
1J0 937 713 A | - | ||
18 | flat contact housing with contact locking mechanism wiring harness for interior possible single wire: 0,5 |
0,5 |
X X |
4B0 972 585 | - | |
19 | flat contact housing with contact locking mechanism wiring harness for interior use if required: possible single wire: |
X 1 X X X X |
1J0 937 714 B | - | ||
20 | flat contact housing with contact locking mechanism airbag wiring harness possible single wire: 1,0 1,0 1,0 1,0 2,5 |
1,0 1,0 1,0 1,0 2,5 |
1 X X X X X |
1J0 937 733 C | - | |
21 | flat contact housing with contact locking mechanism wiring set for headlights wiring set for door electronic siren wiring harness for anti-lock brakesystem -abs- wiring harness for interior possible single wire: |
1 X X X X |
1J0 937 733 D | - | ||
21A | flat contact housing with contact locking mechanism wiring set for headlights possible single wire: |
1 X X X X |
1J0 937 733 B | - | ||
22 | flat contact housing with contact locking mechanism wiring set for headlights use if required: possible single wire: |
X 1 X X |
1J0 937 713 B | - | ||
22A | flat contact housing with contact locking mechanism wiring set for headlights |
1 | 1J0 937 713 D | - | ||
23 | flat contact housing with contact locking mechanism wiring set for loudspeaker use if required: possible single wire: |
2 1 X X |
3B0 937 713 | - | ||
24 | flat contact housing with contact locking mechanism switch for turn signals,main and dip beam, headlight flasher and parking light possible single wire: |
1 X X X |
8L0 971 978 | - | ||
25 | flat contact housing switch for wiper and washer operation possible single wire: |
1 X X X |
893 971 636 | - | ||
25A | flat contact housing connection piece steering col. combi switch possible single wire: |
1 X X |
8L0 972 974 | - | ||
26 | flat contact housing with contact locking mechanism switch for cruise control system possible single wire: F >> 3U-39047 829 |
X X |
8L0 972 980 | - | ||
(26) | flat contact housing with contact locking mechanism switch for cruise control system possible single wire: F 3U-49047 829>> |
X X X |
8E0 971 980 | - | ||
27 | flat contact housing ignition/starter switch possible single wire: |
1 X X X |
8D0 971 975 | - | ||
28 | flat contact housing with contact locking mechanism reader coil possible single wire: F >> 3U-39030 245 |
1 X |
8D0 972 623 AA | - | ||
(28) | flat contact housing with contact locking mechanism reader coil possible single wire: F 3U-39030 246>> |
1 | 4B0 971 832 | - | ||
29 | flat contact housing connection piece airbag impulse sender for coil possible single wire: |
1 X |
1J0 973 605 F | - | ||
30 | flat contact housing with contact locking mechanism switch for cruise control system possible single wire: F >> 3U-39047 828 |
X X |
8L0 972 980 | - | ||
(30) | flat contact housing with contact locking mechanism switch for cruise control system possible single wire: F 3U-49047 829>> |
X X X |
8E0 971 980 | - | ||
31 | flat contact housing cancelling ring with slip ring and steering sensor possible single wire: |
X X |
4B0 971 636 | - | ||
32 | round connector housing for vehicles with front passenger airbag possible single wire: F >> 3U-39010 702 |
X X |
8D0 971 969 | - | ||
(32) | flat contact housing for vehicles with front passenger airbag possible single wire: F 3U-39010 703>> |
1 X |
6X0 972 773 | - | ||
33 | flat contact housing for vehicles with driver airbag possible single wire: |
1 X |
6X0 972 783 | - | ||
34 | flat contact housing with cap connection piece combi-instrument possible single wire: F >> 3U-39047 828 0,5 |
0,5 |
1 X |
8L0 972 977 C | - | |
34 | flat contact housing with cap connection piece combi-instrument possible single wire: F 3U-49047 828>> |
1 X |
1J0 972 977 C | - | ||
35 | flat contact housing with cap connection piece combi-instrument possible single wire: F >> 3U-39047 828 |
1 X |
8L0 972 977 D | - | ||
35 | flat contact housing with cap connection piece combi-instrument possible single wire: F 3U-3-047 829>> |
1 X |
1J0 972 977 D | - | ||
36 | flat contact housing emergency light switch possible single wire: |
1 X X X |
1J0 971 971 | - | ||
37 | flat contact housing with contact locking mechanism switch for heated rear window possible single wire: |
1 X X X X |
6Q0 972 773 A | - | ||
38 | flat contact housing with contact locking mechanism switch for electronic stabilisation program -esp- possible single wire: |
1 | 6Q0 972 773 B | - | ||
39 | flat contact housing with contact locking mechanism switch for traction control possible single wire: |
1 | 6Q0 972 773 D | - | ||
40 | flat connector housing switch for seat heating possible single wire: 1,0 2,5 6,0 |
1,0 2,5 6,0 |
2 X X X |
8L0 971 972 | - | |
40 | flat contact housing with contact locking mechanism switch for heated windscreen window possible single wire: |
2 | 6Q0 972 773 B | - | ||
(40) | flat contact housing with contact locking mechanism key switch for deactivating airbag possible single wire: |
1 | 6Q0 972 773 | - | ||
(40) | flat contact housing possible single wire: for models with the possibility of deactivating the front passenger airbag |
1 X |
6Q0 972 928 | - | ||
41 | flat contact housing connection piece switch for driving headlights possible single wire: |
1 X X |
1J0 972 999 | 2 | ||
42 | flat contact housing controller for instrument lighting possible single wire: 1,0 1,0 1,0 2,5 2,5 |
1,0 1,0 1,0 2,5 2,5 |
1 X X X X X |
1J0 972 924 | - | |
43 | flat contact housing for vehicles with headlight range adjustment possible single wire: |
1 X X X X |
1J0 972 723 | - | ||
44 | rd. connector sleeve housing switch for brake pedal possible single wire: 1,0 2,5 |
1,0 2,5 |
1 X X |
4A0 971 943 | - | |
45 | flat contact housing accelerator pedal with electronic module possible single wire: 1,0 1,0 |
1,0 1,0 |
1 X X |
535 972 706 | - | |
46 | flat contact housing breather valve possible single wire: 1,0 1,0 |
1,0 1,0 |
X X X |
443 906 231 | - | |
47 | flat contact housing with contact locking mechanism connection piece test socket possible single wire: 1,0-1,5 |
1,0-1,5 |
1 X |
8D0 972 695 | - | |
48 | flat contact housing radio possible single wire: |
1 X X |
357 035 447 | - | ||
49 | flat contact housing radio possible single wire: |
1 X X |
357 035 447 A | - | ||
49 | flat contact housing with contact locking mechanism radio possible single wire: PR-7Q5
1,0 1,0 2,5 |
PR-7Q5 1,0 1,0 2,5 |
1 X X X |
357 035 447 B | - | |
50 | flat contact housing with contact locking mechanism radio possible single wire: |
1 | 3B7 035 447 | - | ||
51 | flat contact housing with additional contact lock and additional connector housing mountings radio |
1 | 3B7 035 444 | - | ||
51A | flat contact housing with contact locking mechanism radio possible single wire: |
1 X X X X |
3B7 035 447 B | - | ||
52 | flat contact housing with contact locking mechanism radio possible single wire: |
1 X X X X |
3B7 035 447 A | - | ||
53 | flat contact housing with contact locking mechanism interface possible single wire: 0,5 0,5 |
0,5 0,5 |
1 X X |
3D0 035 131 | - | |
54 | flat contact housing with cap for vehicles with navigation system possible single wire: 0,5 |
0,5 |
1 X |
3B0 919 754 | - | |
55 | flat contact housing navigation unit possible single wire: |
1 | 4A0 972 643 | - | ||
56 | flat contact housing navigation unit possible single wire: |
1 X |
4A0 972 643 A | - | ||
57 | flat contact housing navigation unit possible single wire: |
1 | 4A0 972 643 B | - | ||
58 | flat contact housing with contact locking mechanism control unit for dynamic navigation system possible single wire: F >> 3U-39047 828 0,5 |
0,5 |
1 X |
4A0 972 883 | - | |
(58) | flat contact housing with contact locking mechanism control unit for dynamic navigation system possible single wire: F 3U-49047 829>> 0,5 0,5 |
0,5 0,5 |
1 X X |
8E0 972 112 | - | |
59 | flat contact housing cigarette lighter possible single wire: |
1 X X X |
191 919 321 | - | ||
60 | rd. connector sleeve housing roof wiring harness wiring harness for headlight washer system possible single wire: 1,0 2,5 |
1,0 2,5 |
1 X X |
8A0 972 623 | - | |
61 | flat contact housing switch for handbrake warning light possible single wire: |
1 | 1H0 973 121 C | - | ||
62 | flat contact housing with contact locking mechanism glove compartment lid light possible single wire: |
1 X X |
1J0 972 923 | - | ||
63 | flat contact housing ashtray light possible single wire: |
X X X X |
191 906 231 A | - | ||
64 | flat connector housing with contact locking mechanism air vent light possible single wire: |
X X |
3B0 972 712 | - | ||
65 | flat contact housing with contact locking mechanism air vent light possible single wire: F >> 3U-39047 828 |
1 X |
8D0 972 623 AA | - | ||
(65) | flat contact housing with contact locking mechanism air vent light possible single wire: |
1 X X |
4B0 972 623 | - | ||
66 | flat contact housing with contact locking mechanism interior mirror, automatic anti-dazzle possible single wire: |
1 X X X |
1J0 937 733 | - | ||
67 | diode connector | 1 | 059 905 371 D | - | ||
68 | flat contact housing with contact locking mechanism and grommet diode connector possible single wire: 1,0 2,5 6,0 |
1,0 2,5 6,0 |
2 X X X |
813 972 924 | - | |
69 | round connector housing with rubber grommet diode connector |
1 | 813 972 925 | - | ||
70 | rd. connector sleeve housing sun sensor possible single wire: F >> 3U-39047 828 0,5 |
0,5 |
1 X |
4D0 972 623 | - | |
(70) | flat contact housing with contact locking mechanism sun sensor also to be used for: possible single wire: F 3U-49047 829>> |
1 | 8E0 971 832 | - | ||
71 | flat contact housing with contact locking mechanism display and control panel with cu for electronically controlled air-conditioning possible single wire: F >> 3U-39047 828 0,5 |
0,5 |
1 X |
4A0 972 883 | - | |
(71) | flat contact housing with contact locking mechanism display and control panel with cu for electronically controlled air-conditioning possible single wire: F 3U-49047 829>> 0,5 0,5 |
0,5 0,5 |
1 X X |
8E0 972 112 | - | |
72 | flat contact housing with contact locking mechanism display and control panel with cu for electronically controlled air-conditioning possible single wire: F >> 3U-39047 828 0,5 |
0,5 |
1 X |
4A0 972 883 A | - | |
flat contact housing with contact locking mechanism display and control panel with cu for electronically controlled air-conditioning possible single wire: F 3U-49047 829>> |
1 X X |
8E0 972 416 | - | |||
73 | flat contact housing with contact locking mechanism display and control panel with cu for electronically controlled air-conditioning possible single wire: F >> 3U-39047 828 0,5 |
0,5 |
1 X |
4A0 972 883 B | - | |
(73) | flat contact housing with contact locking mechanism display and control panel with cu for electronically controlled air-conditioning possible single wire: F 3U-49047 829>> |
1 X X |
8E0 972 420 | - | ||
74 | flat contact housing with contact locking mechanism display and control panel with cu for electronically controlled air-conditioning possible single wire: 0,5 1.0 2,5 |
0,5 1.0 2,5 |
1 X X X |
4A0 972 883 C | - | |
75 | flat contact housing for recirculated air operation possibility |
1 | 191 972 724 | 1 | ||
76 | flat contact housing fresh air and heater controls possible single wire: 1,0 2,5 6,0 |
1,0 2,5 6,0 |
1 X X X |
357 959 545 | - | |
77 | flat contact housing fresh air and heater controls possible single wire: 1,0 1,0 |
1,0 1,0 |
1 X X |
3B0 972 705 | - | |
78 | flat contact housing with contact locking mechanism fan control use if required: possible single wire: |
1 1 X X |
1J0 937 713 A | - | ||
79 | flat contact housing with cap central flap positioning motor control motor for temperature regulating flap possible single wire: 0,5 0,5 |
0,5 0,5 |
1 X X |
4B0 972 571 | - | |
80 | flat contact housing connection piece fan possible single wire: 2,5 |
2,5 |
1 X |
8D0 971 959 | - | |
81 | grommet connection piece flat contact housing fan |
1 | 8D0 906 102 B | - | ||
82 | flat contact housing temperature sensor possible single wire: 1,0 1,0 2,5 |
1,0 1,0 2,5 |
X X X X |
893 971 632 | - | |
83 | flat contact housing temperature sensor possible single wire: 1,0 1,0 |
1,0 1,0 |
1 X X |
1H0 972 702 A | - | |
84 | flat connector housing temperature sensor evaporator possible single wire: 1,0 1,0 |
1,0 1,0 |
1 X X |
1J0 971 972 | - | |
85 | flat contact housing with gasket external temperature sensor possible single wire: |
1 X X X |
357 972 752 | 3 | ||
86 | flat contact housing with gasket external temperature sensor air-conditioning system with electronic regulation possible single wire: 1,0 1,0 2,5 |
1,0 1,0 2,5 |
1 X X X |
443 906 232 | - | |
87 | flat contact housing with contact locking mechanism positioning motor for recirculated air operation possible single wire: |
1 X X |
3B0 972 703 | - | ||
88 | flat contact housing series resistor air conditioning possible single wire: |
1 4 |
1J0 972 754 | - | ||
89 | flat contact housing with cap servomotor for defroster flap possible single wire: 0,5 0,5 |
0,5 0,5 |
1 X X |
4B0 972 571 | - | |
90 | flat contact housing for additional heater possible single wire: 1,0 |
1,0 |
1 X |
1J0 972 753 | - | |
91 | relay plate possible single wire: |
X X X X X X X |
443 937 527 | - | ||
92 | double relay carrier possible single wire: |
X X X X X X X |
4A0 937 529 | - | ||
93 | relay plate possible single wire: 1,0 2,5 4,0 |
1,0 2,5 4,0 |
X X X X |
4B0 937 527 | - | |
(93) | relay plate possible single wire: no replacement part |
1 X X |
3C0 973 721 | - | ||
94 | flat contact housing with contact locking mechanism flat fuse 19/2x5 possible single wire: 1,0. 2,5 6,0 |
1,0. 2,5 6,0 |
X | 4B0 937 530 | - | |
95 | additional relay plate | 1 | 4B1 937 503 | - | ||
96 | additional relay plate | 1 | 4B2 937 503 | - | ||
97 | fuse holder flat fuse 29/2x8 possible single wire: |
1 X |
8A0 937 530 | - | ||
98 | bracket for connector housing | 1 | 8D0 937 503 E | - | ||
99 | fuse holder | 1 | 8D1 941 824 | - | ||
100 | fuse holder | 1 | 8D2 941 824 | - | ||
101 | bracket for connector housing | X | 8D0 937 545 E | - | ||
102 | cable holder hole/sheet metal thickness: |
X | 4B0 971 848 | - | ||
103 | cable ties | X | N 020 902 2 | - | ||
104 | cable ties hole/sheet metal thickness: |
X | 3D0 971 838 N | 2 | ||
105 | cable tie with holder for weld pin: |
X | 3D0 971 838 A | - | ||
106 | flat contact housing socket glove compartment possible single wire: |
1 X X |
357 919 321 | - | ||
107 | flat contact housing with contact locking mechanism two-way radio possible single wire: |
1 | 1J0 937 733 | - | ||
108 | flat connector housing with contact locking mechanism two-way radio possible single wire: |
1 | 1J0 937 743 | - | ||
109 | flat connector housing switch for lighting possible single wire: 1,0 2,5 6,0 |
1,0 2,5 6,0 |
X X X X |
8L0 971 972 | - | |
110 | foam tube | 1 | 3B0 971 790 | - | ||
111 | underlay noise insulation |
1 | 867 955 499 | - | ||
112 | foam tube | 1 | 191 035 518 B | - | ||
(112) | foam tube (self-adhesive) |
1 | 171 035 518 B | - | ||
- | terminal connection piece radiator fan |
1 | 1H0 971 939 C | - | ||
- | bracket, self-adhesive | 1 | 4A0 971 849 B | - | ||
- | oval head self-tapping screw | 5 | N 903 565 04 | - | ||
wiring harness for air vent no replacement part comprising: |
||||||
- | flat contact housing with contact locking mechanism coupling element wiring set for dash panel |
1 | 3B0 972 702 | - | ||
- | flat contact housing with contact locking mechanism possible single wire: fresh air vent 0,5 |
0,5 |
4 X |
3B0 973 115 | - | |
- | flat contact housing possible single wire: fresh air vent 0,5 0,5 |
0,5 0,5 |
X X X |
3B0 973 115 A | - | |
- | cable holder hole/sheet metal thickness: |
X | 4B0 971 848 | - | ||
individual parts | ||||||
- | wiring harness for electronic taxameter |
1 | 3B0 971 526 | - | ||
- | flat contact housing socket glove compartment possible single wire: 1,0 2,5 |
1,0 2,5 |
1 X X |
357 919 321 | - | |
flat contact housing with contact locking mechanism two-way radio possible single wire: |
1 | 1J0 937 733 | - | |||
- | flat connector housing with contact locking mechanism two-way radio possible single wire: |
1 X X X X |
1J0 937 743 | - | ||
- | flat connector housing switch for roof sign possible single wire: 1,0 2,5 6,0 |
1,0 2,5 6,0 |
X X X X |
8L0 971 972 | - | |
- | double relay carrier relay for alarm possible single wire: |
X X X X X X X |
4A0 937 529 | - | ||
- | flat contact housing switch alarm system possible single wire: 1,0 1,0 2,5 |
1,0 1,0 2,5 |
X X X X |
893 971 632 | - | |
- | flat connector housing gearshift lever alarm system possible single wire: 1,0 |
1,0 |
X X |
893 971 992 | - | |
- | flat contact housing with contact locking mechanism use if required: wiring harness for electronic taxameter possible single wire: |
1 1 X X |
1J0 937 713 | - | ||
- | relay plate relay for alarm possible single wire: |
X X X X X X X |
443 937 527 | - | ||
- | flat contact housing with contact locking mechanism and grommet possible single wire: 1,0 2,5 6,0 |
1,0 2,5 6,0 |
2 X X X |
813 972 924 | - | |
- | diode connector | 1 | 059 905 371 D | - | ||
- | flat contact housing with contact locking mechanism flat fuse 19/2x5 possible single wire: 1,0. 2,5 6,0 |
1,0. 2,5 6,0 |
2 | 4B0 937 530 | - | |
- | bracket for connector housing | 1 | 8D1 937 545 C | - | ||
- | bracket for connector housing | 1 | 8D2 937 545 E | - |