№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
wiring set for electronically regulated air-conditioning |
||||||
wiring set for electronically regulated air-conditioning F >> 1U-12498 634 F >> 1U-18453 264 |
||||||
(1) | wiring set for electronically regulated air-conditioning |
1 | 1J1 971 566 N | - | ||
(1) | wiring set for electronically regulated air-conditioning mapped cooling |
1 | 1J1 971 566 P | - | ||
(1) | wiring set for electronically regulated air-conditioning |
1 | 1J2 971 566 N | - | ||
(1) | wiring set for electronically regulated air-conditioning mapped cooling |
1 | 1J2 971 566 P | - | ||
wiring set for electronically regulated air-conditioning F 1U-12498 635>> 1U-42840 086 F 1U-18453 265>> 1U-48724 053 |
||||||
(1) | wiring set for electronically regulated air-conditioning |
1 | 1J1 971 566 AK | - | ||
(1) | wiring set for electronically regulated air-conditioning mapped cooling |
1 | 1J1 971 566 AN | - | ||
(1) | wiring set for electronically regulated air-conditioning |
1 | 1J2 971 566 AK | - | ||
(1) | wiring set for electronically regulated air-conditioning mapped cooling |
1 | 1J2 971 566 AN | - | ||
wiring set for electronically regulated air-conditioning F 1U-12498 635>> F 1U-18453 265>> F 1U-7B006 167>> |
||||||
(1) | wiring set for electronically regulated air-conditioning |
1 | 1J1 971 566 BC | - | ||
(1) | wiring set for electronically regulated air-conditioning mapped cooling |
1 | 1J1 971 566 BD | - | ||
(1) | wiring set for electronically regulated air-conditioning |
1 | 1J2 971 566 AP | - | ||
(1) | wiring set for electronically regulated air-conditioning mapped cooling |
1 | 1J2 971 566 AQ | - | ||
individual parts | ||||||
3 | flat contact housing connection piece fan possible single wire: |
1 | 1J0 959 971 | - | ||
(3B) | cable tie with holder for plastic pin: |
X | 8L0 971 838 | - | ||
(3B) | bracket connection piece a-pillar |
X | 1J5 971 003 | - | ||
(4) | flat connector housing connection piece temperature sensor evaporator housing possible single wire: F 1U-12498 638>>* F 1U-18453 264>>* F 1U-7B006 167>> |
1 |
1J0 971 972 | - | ||
4 | flat contact housing with contact locking mechanism connection piece temperature sensor intake air duct possible single wire: |
1 | 1J0 972 923 | - | ||
(4A) | flat contact housing with contact locking mechanism connection piece temperature sensor footwell vent possible single wire: |
1 | 3B0 972 702 | - | ||
5 | flat contact housing connection piece ventilation flap possible single wire: |
1 | 535 972 705 | - | ||
6 | flat contact housing with contact locking mechanism coupling element wiring harness for interior possible single wire: |
1 | 6Q0 972 736 | - | ||
(6) | flat contact housing with contact locking mechanism coupling element wiring harness for interior possible single wire: |
1 | 6Q0 972 777 | - | ||
7 | flat contact housing connection piece fan motor possible single wire: |
1 | 1J0 959 971 | - | ||
(7) | flat contact housing with contact locking mechanism connection piece temperature sensor possible single wire: |
1 | 1J0 972 923 | - | ||
(8) | flat contact housing connection piece fan control possible single wire: |
1 | 1J0 972 753 | - | ||
9 | flat contact housing with contact locking mechanism connection piece heater with fresh air and heating control possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 |
1 | 4A0 972 883 | - | ||
(9) | flat contact housing with contact locking mechanism connection piece heater with fresh air and heating control possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 0,5 0,5 |
0,5 0,5 |
1 X X |
8E0 972 112 | - | |
10 | flat contact housing with contact locking mechanism connection piece fresh air and heater controls possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 2 |
2 |
1 | 4A0 972 883 A | - | |
(10) | flat contact housing with contact locking mechanism connection piece fresh air and heater controls possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 2 |
2 |
1 X X |
8E0 972 416 | - | |
11 | flat contact housing with contact locking mechanism connection piece fresh air and heater controls possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 |
1 | 4A0 972 883 B | - | ||
(11) | flat contact housing with contact locking mechanism connection piece fresh air and heater controls possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 2 |
2 |
1 X X |
8E0 972 420 | - | |
12 | flat contact housing with contact locking mechanism connection piece fresh air and heater controls possible single wire: |
1 | 4A0 972 883 C | - | ||
16 | flat contact housing connection piece central flap positioning motor servomotor possible single wire: F >> 1U-42830 086 F >> 1U-48724 053 2 |
2 |
X 1 2 |
7M0 973 119 | - | |
(16) | flat contact housing with contact locking mechanism connection piece central flap positioning motor servomotor possible single wire: F 1U-42830 087>> F 1U-48724 054>> F 1U-7B006 167>> 2 |
2 |
1 | 6Q0 972 706 | - |