№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
wiring harness for interior list of uses coupling st. connector housing fuse holder |
||||||
list of uses coupling st. connector housing |
||||||
- | the connector housing is found in the individual position of the component see parts bulletin: |
|||||
- | * corrug. tubes, t-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * electrical * connecting elements |
|||||
1 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for engine wiring harness for gearbox wiring set for fuel tank |
X 1 1 1 |
5Q0 973 737 | - | ||
(1) | flat contact housing with contact locking mechanism for contact housing: |
X | 5Q0 973 837 | - | ||
(1) | bracket for connector housing | 1 | 3B0 919 136 A | - | ||
2 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for engine rear axle |
X 1 1 |
3C0 973 737 | - | ||
(2) | flat contact housing with contact locking mechanism to use for: for contact housing: |
X | 5Q0 973 837 | - | ||
3 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for bumper wiring set for engine |
X 1 1 |
4H0 973 717 | - | ||
(3) | flat contact housing with contact locking mechanism for contact housing: |
1 | 6X0 973 817 | 1 | ||
4 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for electro- mechanical power steering valve block PR-0K3 |
PR-0K3 |
X 1 1 |
8K0 973 703 | - | |
(4) | flat contact housing with contact locking mechanism for contact housing: |
X | 1J0 973 803 | 1 | ||
5 | flat contact housing use if required: coupling element wiring set for engine |
1 | 8D0 973 734 | - | ||
(5) | flat contact housing for contact housing: |
1 | 8D0 973 834 | - | ||
6 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for engine |
1 | 4H0 973 714 | - | ||
(6) | flat contact housing for contact housing: |
1 | 1J0 973 814 | 1 | ||
7 | flat contact housing with contact locking mechanism use if required: coupling element adapter cable sensor for longit. accelerat. -crash sensor |
2 | 8V0 973 803 | - | ||
(7) | flat contact housing with contact locking mechanism for contact housing: |
2 | 8V0 973 703 | - | ||
(7) | cable holder for contact housing: |
2 | 8P0 971 848 D | - | ||
8 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for engine wiring set for bumper wiring harness for gearbox |
X 1 1 1 |
4H0 973 713 | - | ||
(8) | flat connector housing with contact locking mechanism for contact housing: |
X | 3B0 973 813 | 1 | ||
9 | flat contact housing use if required: coupling element wiring set for three-phase alternator |
1 | 5C6 973 752 | - | ||
(9) | flat connector housing with contact locking mechanism for contact housing: |
1 | 1J0 973 852 | - | ||
10 | flat contact housing with contact locking mechanism coupling element for diagnostic plug |
1 | 3A0 972 695 A | - | ||
11 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for door |
2 | 4M0 972 701 | - | ||
(11) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4M0 972 702 | - | ||
12 | flat connector housing with contact locking mechanism use if required: coupling element wiring set for dash panel |
2 | 4F0 972 575 B | - | ||
(12) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4F0 972 483 B | - | ||
13 | flat connector housing with contact locking mechanism also to be used for: use if required: coupling element wiring set for dash panel wiring set for tail light |
X 1 1 |
4F0 972 575 | - | ||
(13) | flat contact housing with contact locking mechanism also to be used for: for contact housing: |
X | 4F0 972 483 | - | ||
14 | flat connector housing with contact locking mechanism use if required: coupling element wiring set for dash panel |
2 | 4F0 972 575 D | - | ||
(14) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4F0 972 483 D | - | ||
15 | flat connector housing with contact locking mechanism also to be used for: use if required: coupling element wiring set for dash panel |
2 | 4F0 972 575 A | - | ||
(15) | flat contact housing with contact locking mechanism also to be used for: for contact housing: |
2 | 4F0 972 483 A | - | ||
16 | coupling element flat connector fibre optic wave conductor use if required: |
1 | 4E0 973 302 | - | ||
(16) | flat connector fibre optic wave conductor for contact housing: |
1 | 4E0 973 702 | - | ||
17 | flat connector housing with contact locking mechanism use if required: coupling element wiring harness for interior |
2 | 8E0 972 763 | - | ||
(17) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4B0 972 623 | - | ||
18 | flat contact housing use if required: coupling element wiring harness for gearbox |
1 | 1J0 973 714 | 1 | ||
(18) | flat contact housing for contact housing: |
1 | 1J0 973 814 | 1 | ||
19 | flat contact housing with contact locking mechanism use if required: coupling element wiring harness for gearbox |
1 | 8K0 973 702 | - | ||
(19) | flat connector housing with contact locking mechanism for contact housing: |
1 | 1J0 973 802 | 1 | ||
20 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for multimedia equipment |
1 | 95B 972 728 | - | ||
(20) | flat contact housing with contact locking mechanism for contact housing: |
1 | 1K0 972 928 | - | ||
(20) | bracket for connector housing for contact housing: |
1 | 4M0 937 545 F | - | ||
21 | removable housing for aerial pin connector to use for: use if required: coupling element wiring set for multimedia equipment |
1 | 6Q0 035 575 K | - | ||
(21) | removable housing for aerial female connector to use for: for contact housing: |
1 | 6Q0 035 576 K | - | ||
22 | flat connector housing with contact locking mechanism use if required: coupling element seat frame wiring harness |
2 | 4F0 972 575 B | - | ||
(22) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4F0 972 483 B | - | ||
23 | flat connector housing use if required: coupling element seat frame wiring harness |
2 | 8K0 972 974 | - | ||
(23) | flat contact housing for contact housing: |
2 | 8K0 973 754 | - | ||
24 | flat contact housing use if required: coupling element seat frame wiring harness seat frame wiring harness |
X 2 2 |
4G0 972 783 | - | ||
(24) | flat contact housing with contact locking mechanism for contact housing: |
X | 4H0 972 773 | - | ||
25 | flat contact housing also to be used for: use if required: coupling element seat frame wiring harness seat frame wiring harness wiring set for dash panel |
X 2 2 1 |
4F0 937 741 | - | ||
(25) | flat contact housing with contact locking mechanism also to be used for: for contact housing: |
X | 4F0 937 731 | - | ||
(25) | bracket for connector housing hole/sheet metal thickness: |
1 | 4L0 937 545 A | - | ||
26 | flat connector housing with contact locking mechanism use if required: coupling element seat frame wiring harness |
2 | 4F0 937 743 | - | ||
(26) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4F0 937 733 | - | ||
27 | flat connector housing with contact locking mechanism for sheet metal thickness: use if required: coupling element wiring set for door |
2 | 4M0 937 722 | - | ||
(27) | flat contact housing with contact locking mechanism for contact housing: |
2 | 5G0 937 702 | - | ||
28 | flat connector housing use if required: coupling element seat frame wiring harness |
2 | 8K0 972 994 | - | ||
(28) | flat contact housing for contact housing: |
1 | 8K0 973 754 | - | ||
29 | flat connector housing use if required: coupling element seat frame wiring harness |
1 | 8K0 972 994 A | - | ||
(29) | flat contact housing for contact housing: |
1 | 8K0 973 754 A | - | ||
30 | flat contact housing with contact locking mechanism use if required: coupling element harness for air conditioner |
1 | 8E0 971 980 | - | ||
(30) | flat connector housing with contact locking mechanism for contact housing: |
1 | 1K0 971 992 | - | ||
31 | flat contact housing use if required: coupling element high-voltage wiring set for high-voltage battery PR-0K3
|
PR-0K3 | 1 | 8K0 973 754 | - | |
(31) | flat connector housing for contact housing: |
1 | 8K0 972 994 | - | ||
32 | flat contact housing use if required: coupling element high-voltage wiring set for high-voltage battery PR-0K3
|
PR-0K3 | 1 | 1J0 973 814 | 1 | |
(32) | flat contact housing for contact housing: |
1 | 1J0 973 714 | 1 | ||
33 | removable housing for aerial female connector to use for: use if required: coupling element aerial cable |
X | 6Q0 035 608 K | - | ||
(33) | removable housing for aerial pin connector for contact housing: |
X | 6Q0 035 671 K | - | ||
(33) | bracket for connector housing for contact housing: |
1 | 4M0 937 545 D | - | ||
34 | flat contact housing use if required: coupling element for vehicles with heated windscreen |
1 | 1J0 973 332 | - | ||
(34) | flat contact housing with contact locking mechanism for contact housing: |
1 | 1J0 973 119 | - | ||
35 | flat contact housing use if required: coupling element high-voltage wiring set for high-voltage battery |
1 | 6R0 973 735 | - | ||
(35) | flat contact housing with contact locking mechanism for contact housing: |
1 | 1J0 973 835 | 1 | ||
36 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for tow hitch seat frame wiring harness |
X 1 2 |
1J0 972 923 | - | ||
(36) | flat connector housing for contact housing: |
X | 191 972 712 | 1 | ||
37 | flat contact housing with contact locking mechanism use if required: coupling element high-voltage wiring set for high-voltage battery |
1 | 8K0 973 704 A | - | ||
(37) | flat contact housing with contact locking mechanism for contact housing: |
1 | 1K0 973 804 A | - | ||
38 | flat contact housing use if required: coupling element rear axle |
1 | 4G0 906 234 B | - | ||
(38) | round connector housing for contact housing: |
1 | 4G0 906 444 | - | ||
39 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for bumper |
1 | 8K0 972 416 | - | ||
(39) | flat contact housing with contact locking mechanism for contact housing: |
1 | 8E0 972 416 A | - | ||
40 | flat contact housing use if required: coupling element seat frame wiring harness |
1 | 8K0 973 754 | - | ||
(40) | flat connector housing for contact housing: |
1 | 8K0 972 994 | - | ||
41 | flat contact housing use if required: coupling element seat frame wiring harness |
1 | 6R0 972 930 A | - | ||
(41) | flat connector housing with contact locking mechanism for contact housing: |
1 | 1K0 971 992 A | - | ||
42 | flat contact housing with contact locking mechanism use if required: coupling element seat frame wiring harness |
1 | 6R0 972 930 | - | ||
(42) | flat connector housing with contact locking mechanism for contact housing: |
1 | 1K0 971 992 | - | ||
- | maintenance connector for high voltage system use if required: |
1 | 4J0 973 704 | - | ||
- | bracket for connector housing for contact housing: |
1 | 5QE 937 510 | - | ||
fuse holder | ||||||
51 | fuse holder also to be used for: contact bridge use if required: |
X | 4H0 941 824 | - | ||
(51) | rescue marking | 1 | 12E 010 867 Q | - | ||
52 | fuse holder also to be used for: contact bridge |
X | 4F1 941 824 | - | ||
53 | fuse holder also to be used for: |
X | 8W0 937 530 | - | ||
54 | fuse holder | X | 4A0 937 530 | - | ||
55 | fuse holder contact bridge |
1 | 8K0 941 824 D | - | ||
56 | fuse holder contact bridge also to be used for: |
1 | 8K0 941 824 | - |