№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
wiring harness for interior list of uses coupling st. connector housing |
||||||
list of uses coupling st. connector housing |
||||||
- | the connector housing is found in the individual position of the component see parts bulletin: |
|||||
- | * corrug. tubes, t-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * electrical * connecting elements |
|||||
- | fuse holder relay plate grommets data connection line see illustration: |
|||||
1 | flat contact housing with contact locking mechanism coupling element for diagnostic plug |
1 | 3A0 972 695 A | - | ||
3 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for door |
4 | 8K0 972 701 | - | ||
(3) | flat contact housing with contact locking mechanism for contact housing: |
4 | 8K0 972 702 | - | ||
4 | flat connector housing with contact locking mechanism use if required: coupling element wiring set for engine |
1 | 3AA 972 714 | - | ||
(4) | flat contact housing with contact locking mechanism for contact housing: |
1 | 8V0 972 704 | - | ||
5 | flat connector housing with contact locking mechanism also to be used for: use if required: coupling element harness for engine compartment |
1 | 4F0 972 575 A | - | ||
(5) | flat contact housing with contact locking mechanism also to be used for: for contact housing: |
1 | 4F0 972 483 A | - | ||
6 | flat contact housing use if required: coupling element wiring set for engine |
1 | 4G0 906 234 B | - | ||
(6) | round connector housing for contact housing: |
1 | 4G0 906 444 | - | ||
7 | flat contact housing with contact locking mechanism use if required: coupling element harness for engine compartment |
1 | 8K0 972 483 D | - | ||
(7) | flat connector housing with contact locking mechanism for contact housing: |
1 | 4F0 972 575 D | - | ||
8 | flat contact housing with contact locking mechanism use if required: coupling element harness for engine compartment |
1 | 8K0 972 483 | - | ||
(8) | flat connector housing with contact locking mechanism for contact housing: |
1 | 4F0 972 575 | - | ||
9 | flat contact housing with contact locking mechanism use if required: coupling element harness for engine compartment |
1 | 8K0 972 483 A | - | ||
(9) | flat connector housing with contact locking mechanism for contact housing: |
1 | 4F0 972 575 A | - | ||
10 | flat contact housing with contact locking mechanism use if required: coupling element harness for engine compartment |
1 | 8K0 972 483 B | - | ||
(10) | flat connector housing with contact locking mechanism for contact housing: |
1 | 4F0 972 575 B | - | ||
12 | flat connector housing with contact locking mechanism use if required: coupling element seat frame wiring harness sensor cables |
X 2 1 |
4F0 937 743 B | - | ||
(12) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4F0 937 733 B | - | ||
13 | flat contact housing use if required: coupling element seat frame wiring harness |
2 | 4F0 937 741 | - | ||
(13) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4F0 937 731 | - | ||
14 | flat contact housing use if required: coupling element seat frame wiring harness |
2 | 8R0 973 705 | - | ||
(14) | flat contact housing for contact housing: |
2 | 8R0 973 605 | - | ||
15 | flat contact housing use if required: coupling element seat frame wiring harness |
2 | 4G0 972 783 | - | ||
(15) | flat contact housing with contact locking mechanism for contact housing: |
2 | 4H0 972 773 | - | ||
16 | flat contact housing with contact locking mechanism use if required: coupling element seat frame wiring harness |
1 | 7L0 972 762 | - | ||
(16) | flat contact housing with contact locking mechanism for contact housing: |
1 | 8E0 972 710 | - | ||
17 | flat contact housing with contact locking mechanism use if required: coupling element for special vehicles PR-F6M
|
PR-F6M | 1 | 6Q0 972 726 | - | |
(17) | flat contact housing with contact locking mechanism for contact housing: PR-F6M
|
PR-F6M | 1 | 6Q0 972 736 | - | |
18 | flat contact housing use if required: coupling element wiring set for fuel tank |
1 | 1J0 973 753 | - | ||
(18) | flat contact housing for contact housing: |
1 | 6Q0 973 853 | - | ||
19 | flat contact housing with contact locking mechanism use if required: coupling element electronic differential lock xdl |
1 | 4H0 973 713 | - | ||
(19) | flat connector housing with contact locking mechanism for contact housing: |
1 | 3B0 973 813 | 1 | ||
20 | round connector housing with contact locking mechanism use if required: coupling element wiring set for tow hitch |
1 | 1J0 972 761 | - | ||
(20) | flat contact housing for contact housing: |
1 | 1J0 972 751 | - | ||
21 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for bumper for vehicles with lane change assist for vehicles with selective catalytic reduction (scr) |
X 1 1 1 |
4H0 973 715 | - | ||
(21) | flat contact housing with contact locking mechanism for contact housing: |
X | 6X0 973 815 | - | ||
22 | flat contact housing with contact locking mechanism use if required: coupling element wiring set for bumper |
X 1 |
4H0 973 714 | - | ||
(22) | flat contact housing for contact housing: |
X | 1J0 973 814 | 1 | ||
23 | flat contact housing use if required: coupling element wiring harness for convertible top frame operation |
1 | 1J0 972 732 | - | ||
(23) | flat contact housing for contact housing: |
1 | 1J0 972 722 | - | ||
(23) | bracket for connector housing | 1 | 3D0 971 497 B | - | ||
24 | flat contact housing with contact locking mechanism use if required: coupling element wiring harness for convertible top frame operation cable set for tailgate |
X 1 1 |
4F0 972 112 | - | ||
(24) | flat contact housing with cap for contact housing: |
1 | 8Z0 972 112 | - | ||
25 | rd. connector sleeve housing | 1 | 1K0 971 978 | - | ||
26 | flat contact housing use if required: coupling element cable set for tailgate |
2 | 3B0 972 722 | - | ||
(26) | flat contact housing for contact housing: |
2 | 3B0 972 732 | - | ||
27 | flat contact housing with contact locking mechanism use if required: coupling element cable set for tailgate |
1 | 6Q0 972 736 | - | ||
(27) | flat contact housing with contact locking mechanism for contact housing: |
1 | 6Q0 972 726 | - | ||
(27) | bracket for connector housing | 1 | 3D0 971 830 D | - | ||
28 | removable housing for aerial female connector to use for: use if required: coupling element cable set for tailgate |
X | 6Q0 035 576 K | - | ||
(28) | removable housing for aerial pin connector to use for: for contact housing: |
X | 6Q0 035 575 K | - | ||
29 | flat contact housing use if required: coupling element cable set for tailgate |
1 | 4D0 973 725 | - | ||
(29) | flat contact housing for contact housing: |
1 | 6X0 973 825 | - | ||
33 | flat contact housing with contact locking mechanism use if required: coupling element diagnosis pump for fuel system |
1 | 8K0 973 705 | - | ||
(33) | flat connector housing for contact housing: |
1 | 8K0 973 805 | - | ||
34 | flat connector housing with contact locking mechanism use if required: coupling element wiring harness for interior |
1 | 8E0 972 763 | - | ||
(34) | flat contact housing with contact locking mechanism for contact housing: |
1 | 4B0 972 623 | - |