№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
control unit (bcm) for conv. system & ob power supply diagnosis interface for data bus (gateway) |
||||||
control unit (bcm) for conv. system & ob power supply PR-5D1,5D2
|
PR-5D1,5D2 | |||||
(1) | onboard supply control unit D >> - 07.12.2014 PR-5D1
|
PR-5D1 | 1 | 5Q0 937 086 AA | - | |
onboard supply control unit | 5Q0 937 086 AAZ 0A | - | ||||
(1) | onboard supply control unit D >> - 07.12.2014 PR-5D2
|
PR-5D2 | 1 | 5Q0 937 087 P | - | |
onboard supply control unit | 5Q0 937 087 P Z 08 | - | ||||
(1) | onboard supply control unit D - 08.12.2014>> - 28.06.2015 also to be used for: |
1 | 5Q0 937 086 AE | - | ||
onboard supply control unit PR-QQ0
|
PR-QQ0 | 5Q0 937 086 AEZ 13 | - | |||
onboard supply control unit PR-QQ3
|
PR-QQ3 | 5Q0 937 086 AEZ 14 | - | |||
(1) | onboard supply control unit D - 08.12.2014>> - 28.06.2015 also to be used for: |
1 | 5Q0 937 087 S | - | ||
onboard supply control unit PR-QQ0
|
PR-QQ0 | 5Q0 937 087 S Z 0S | - | |||
onboard supply control unit PR-QQ3
|
PR-QQ3 | 5Q0 937 087 S Z 0T | - | |||
(1) | onboard supply control unit D - 29.06.2015>> - 11.12.2016 also to be used for: |
1 | 5Q0 937 086 AK | - | ||
onboard supply control unit | 5Q0 937 086 AKZ 00 | - | ||||
(1) | onboard supply control unit D - 29.06.2015>> - 11.12.2016 also to be used for: |
1 | 5Q0 937 087 AB | - | ||
onboard supply control unit | 5Q0 937 087 ABZ 00 | - | ||||
diagnosis interface for data bus (gateway) D >> - 08.12.2014 |
||||||
(3) | diagnosis interface for data bus (gateway) also to be used for: |
1 | 5Q0 907 530 T | - | ||
diagnosis interface for data bus (gateway) PR-7L6+AV1
|
PR-7L6+AV1 | 5Q0 907 530 T Z 01 | - | |||
diagnosis interface for data bus (gateway) PR-7L3+AV1
|
PR-7L3+AV1 | 5Q0 907 530 T Z 02 | - | |||
diagnosis interface for data bus (gateway) PR-7L6+AV2
|
PR-7L6+AV2 | 5Q0 907 530 T Z 05 | - | |||
diagnosis interface for data bus (gateway) PR-7L3+AV2
|
PR-7L3+AV2 | 5Q0 907 530 T Z 06 | - | |||
diagnosis interface for data bus (gateway) D - 08.12.2014>> - 29.06.2015 |
||||||
(3) | diagnosis interface for data bus (gateway) also to be used for: |
1 | 5Q0 907 530 AC | - | ||
diagnosis interface for data bus (gateway) PR-7L6+AV1
|
PR-7L6+AV1 | 5Q0 907 530 ACZ 03 | - | |||
diagnosis interface for data bus (gateway) PR-7L3+AV1
|
PR-7L3+AV1 | 5Q0 907 530 ACZ 04 | - | |||
diagnosis interface for data bus (gateway) PR-7L6+AV2
|
PR-7L6+AV2 | 5Q0 907 530 ACZ 0B | - | |||
diagnosis interface for data bus (gateway) PR-7L3+AV2
|
PR-7L3+AV2 | 5Q0 907 530 ACZ 0C | - | |||
diagnosis interface for data bus (gateway) D - 29.06.2015>> - 06.12.2015 |
||||||
(3) | diagnosis interface for data bus (gateway) also to be used for: |
1 | 5Q0 907 530 AF | - | ||
diagnosis interface for data bus (gateway) |
5Q0 907 530 AFZ 00 | - | ||||
diagnosis interface for data bus (gateway) D - 07.12.2015>> |
||||||
(3) | diagnosis interface for data bus (gateway) also to be used for: |
1 | 5Q0 907 530 AJ | - | ||
fasteners | ||||||
5 | retainer for control unit | 1 | 5Q1 941 395 | - | ||
7 | speed nut | 3 | N 903 275 04 | - | ||
8 | hex collared bolt | 3 | N 910 799 01 | - |