№ | Name | Ext. inf. | A* | Use of | Part number |
---|---|---|---|---|---|
individual parts wiring harness for interior area: interior right |
interior right |
||||
- | the connector housing is found in the individual position of the component see parts bulletin: (9-87) |
(9-87) |
|||
- | * corrug. tubes, t-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * electrical * connecting elements ------------------------------ |
||||
- | list of uses coupling st. connector housing see illustration: 971-079 |
971-079 |
|||
- | cable guide mounting for relay plate mounting for fuse holder see illustration: 971-080 |
971-080 |
|||
- | wiring harness for speed sensor see illustration: 927-000 |
927-000 |
|||
- | adapter aerial wire see catalogue: |
||||
- | flat contact housing | X | 893 971 634 | ||
- | removable housing for aerial female connector to use for: |
X | 6Q0 035 576 K | ||
- | flat contact housing | X | 161 971 989 C | ||
- | flat contact housing with contact locking mechanism |
X | 4F0 973 703 | ||
- | flat contact housing with contact locking mechanism |
X | 4H0 973 703 | ||
- | round connector hsg with cable | X | 8T0 971 259 B | ||
- | round connector hsg with cable | X | 8T0 971 259 A | ||
- | round connector hsg with cable | X | 5M1 971 581 | ||
- | flat contact housing | X | 8K0 973 724 | ||
- | flat contact housing with contact locking mechanism |
X | 1J0 973 726 | ||
- | flat contact housing with contact locking mechanism |
X | 4H0 973 713 | ||
- | flat contact housing with contact locking mechanism use if required: 6H0 971 921 C |
6H0 971 921 C |
X | 8K0 973 702 | |
- | flat contact housing with contact locking mechanism |
X | 4E0 971 942 | ||
- | flat contact housing with contact locking mechanism |
X | 4B0 971 832 | ||
- | flat contact housing with contact locking mechanism |
X | 8K0 973 323 S | ||
- | flat contact housing with contact locking mechanism |
X | 8J0 972 586 A | ||
- | flat contact housing with contact locking mechanism |
X | 8J0 972 586 | ||
- | flat connector housing | X | 1J0 971 972 | ||
- | removable housing for aerial bracket female connector |
X | 4E0 035 610 K | ||
- | flat contact housing with contact locking mechanism also to be used for: |
X | 4B0 972 623 | ||
- | flat contact housing | X | 3B0 972 722 | ||
- | flat contact housing | X | 893 971 632 | ||
- | flat contact housing | X | 1J0 919 321 | ||
- | flat contact housing | X | 8K0 973 754 A | ||
- | flat contact housing | X | 8K0 973 754 | ||
- | flat contact housing with contact locking mechanism |
X | 1T0 972 703 | ||
- | flat contact housing also to be used for: |
X | 893 971 633 | ||
- | flat contact housing with contact locking mechanism |
X | 1J0 972 923 | ||
- | flat contact housing with contact locking mechanism |
X | 3B0 972 724 | ||
- | flat contact housing with contact locking mechanism |
X | 1J0 973 119 | ||
- | flat contact housing with contact locking mechanism |
X | 8K0 973 373 | ||
- | flat contact housing with contact locking mechanism use if required: 4B0 906 102 |
4B0 906 102 |
X | 1J0 973 752 | |
- | grommet | X | 4B0 906 102 | ||
- | flat contact housing with contact locking mechanism use if required: 6H0 971 921 C |
6H0 971 921 C |
X | 8K0 973 702 A | |
- | bracket protective cover for contact housing: |
X | 6H0 971 921 C | ||
- | flat contact housing with contact locking mechanism use if required: 1E0 971 921 |
1E0 971 921 |
X | 4B0 973 712 | |
- | bracket protective cover for contact housing: |
X | 1E0 971 921 | ||
- | flat contact housing with contact locking mechanism use if required: 1E0 971 921 6N0 906 102 |
1E0 971 921 6N0 906 102 |
X | 4B0 973 712 A | |
- | flat contact housing with contact locking mechanism |
X | 4F0 972 483 A | ||
- | flat contact housing with cap |
X | 1J0 972 977 D | ||
- | flat contact housing with cap |
X | 1J0 972 977 | ||
- | flat contact housing with cap |
X | 1J0 972 977 G | ||
- | flat contact housing with contact locking mechanism |
X | 4F0 972 483 | ||
- | flat contact housing with contact locking mechanism |
X | 6Q0 972 883 B | ||
- | flat connector housing with contact locking mechanism |
X | 1K0 972 930 A | ||
- | flat contact housing with contact locking mechanism |
X | 6Q0 937 713 | ||
- | flat contact housing with contact locking mechanism |
X | 8E0 971 832 | ||
- | flat contact housing with gasket use if required: 1J0 906 102 |
1J0 906 102 |
X | 8T0 973 702 | |
- | grommet 8,2X40
|
8,2X40 | X | 1J0 906 102 | |
- | flat contact housing with contact locking mechanism use if required: 1J0 906 102 |
1J0 906 102 |
X | 1J0 973 702 | |
- | flat contact housing use if required: 6N0 906 102 |
6N0 906 102 |
X | 1J0 973 713 | |
- | grommet 11,9X53
|
11,9X53 | X | 6N0 906 102 | |
- | flat contact housing use if required: 6N0 906 102 |
6N0 906 102 |
X | 3B0 973 722 A | |
- | flat contact housing with contact locking mechanism |
X | 6Q0 972 706 | ||
- | flat contact housing with cap to use for: use if required: 4F0 973 863 D 1S0 971 904 A |
4F0 973 863 D 1S0 971 904 A |
X | 3C0 973 763 A | |
- | sealing pin 0,63
|
0,63 | X | 1S0 971 904 A | |
- | flat contact housing with contact locking mechanism |
X | 8E0 972 420 B | ||
- | flat contact housing with contact locking mechanism |
X | 8E0 972 416 A | ||
- | flat contact housing with contact locking mechanism |
X | 8E0 972 710 | ||
- | flat contact housing with contact locking mechanism |
X | 7L0 973 047 | ||
- | flat contact housing with contact locking mechanism |
X | 8E0 972 112 B | ||
- | flat contact housing with contact locking mechanism and grommet |
X | 4F0 972 709 | ||
- | flat contact housing with contact locking mechanism |
X | 4F0 973 718 | ||
- | flat contact housing | X | 4F0 973 715 | ||
- | flat contact housing with contact locking mechanism |
X | 6Q0 973 047 | ||
- | flat contact housing with contact locking mechanism |
X | 8E0 973 202 | ||
- | flat contact housing with contact locking mechanism |
X | 4E0 972 144 | ||
- | flat contact housing | X | 8K0 971 833 | ||
- | flat contact housing with contact locking mechanism |
X | 4F0 937 733 B | ||
- | flat contact housing with contact locking mechanism |
X | 4H0 973 713 B | ||
- | flat contact housing with contact locking mechanism |
X | 4H0 973 713 F | ||
- | flat contact housing with contact locking mechanism |
X | 4H0 973 713 C | ||
- | flat contact housing with contact locking mechanism |
X | 8K0 973 705 G | ||
- | flat contact housing with contact locking mechanism |
X | 8K0 973 704 B | ||
- | flatcontact housing with cable | X | 8T0 972 571 B | ||
- | flat contact housing with contact locking mechanism |
X | 4F0 973 702 | ||
- | flat contact housing | X | 4H0 973 702 A | ||
- | flat contact housing with contact locking mechanism |
X | 8K0 973 812 A | ||
- | flat contact housing with contact locking mechanism |
X | 4E0 973 812 A | ||
- | suppression condenser for vehicles with high mounted brake light |
X | 8K0 971 170 | ||
- | flat contact housing | X | 6N0 971 921 | ||
- | flat contact housing | X | 1J0 972 752 | ||
- | removable housing for aerial female connector to use for: |
X | 6Q0 035 608 K |