№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
individual parts wiring harness for interior area: |
||||||
* corrug. tubes, t-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * electrical * connecting elements ------------------------------ |
||||||
cable guide and relay plate see illustration: |
||||||
additional wiring harness for dash panel see illustration: |
||||||
wiring harness for speed sensor see illustration: |
||||||
adapter aerial wire see catalogue: |
||||||
1 | flat contact housing with contact locking mechanism coupling element wiring set for door |
1 | 8H0 972 701 | - | ||
2 | flat contact housing with contact locking mechanism connection piece treble speaker |
1 | 4B0 971 832 | - | ||
3 | removable housing for aerial female connector to use for: connection piece aerial amplifier amplifiers control unit for digital radio reception |
X 1 1 1 |
6Q0 035 576 K | - | ||
4 | flat contact housing with contact locking mechanism coupling element side airbag wiring harness |
1 | 8J0 972 586 | - | ||
5 | flat connector housing with contact locking mechanism coupling element wiring harness for electrically adjustable seat |
1 | 4F0 937 743 B | - | ||
6 | flat contact housing coupling element wiring light for seat heating |
1 | 4F0 937 741 | - | ||
7 | flat connector housing with contact locking mechanism coupling element wire set for models with seat occupant detection |
1 | 4F0 937 743 | - | ||
8 | round connector hsg with cable connection piece three-point safety belt |
1 | 4F0 972 562 | - | ||
8 | round connector hsg with cable connection piece three-point safety belt |
1 | 4F0 971 259 | - | ||
(8) | round connector hsg with cable connection piece three-point safety belt |
1 | 5M1 971 581 | - | ||
8A | flat contact housing with contact locking mechanism connection piece roll bar |
1 | 3D0 972 752 | - | ||
9 | flat contact housing with contact locking mechanism connection piece lateral acceleration sensor -crashsensor- |
1 | 6Q0 972 623 B | - | ||
10 | flat connector housing with contact locking mechanism also to be used for: coupling element wiring set for engine |
2 | 4F0 972 575 | - | ||
11 | flat connector housing with contact locking mechanism coupling element wiring set for engine |
1 | 4F0 972 575 A | - | ||
12 | flat connector housing with contact locking mechanism coupling element wiring set for engine |
1 | 4F0 972 575 B | - | ||
13 | flat contact housing with contact locking mechanism connection piece control unit for electronic regulated damping |
1 | 7L0 973 047 | - | ||
14 | grommet area: |
1 | 8Z0 971 841 A | - | ||
15 | flat contact housing connection piece fuel delivery unit and sender for fuel gauge |
2 | 1K0 919 231 | - | ||
16 | flat contact housing connection piece fuel pump |
1 | 6N0 973 755 | - | ||
17 | flat contact housing connection piece fuel filler neck fuel tank |
X 1 1 |
6N0 971 921 | - | ||
18 | flat contact housing with contact locking mechanism connection piece water level sender |
1 | 1J0 973 202 | - | ||
18A | flat contact housing with contact locking mechanism sill trim strip |
1 | 8K0 973 702 | - | ||
18B | flat contact housing with contact locking mechanism connection piece diagnosis pump for fuel system |
1 | 3D0 973 703 | 2 | ||
19 | flat connector housing with contact locking mechanism use if required: coupling element for rear window, heated |
1 | 1J0 973 852 | - | ||
20 | bracket for connector housing for contact housing: |
1 | N 906 851 01 | - | ||
21 | flat connector housing with contact locking mechanism connection piece fuel filler flap |
1 | 4D0 971 992 | - | ||
22 | flat contact housing with contact locking mechanism connection piece engine compartment lighting |
1 | 8E0 973 202 | - | ||
23 | flat contact housing with contact locking mechanism sender for tyre pressure monitoring system |
1 | 8E0 971 934 | - | ||
24 | flat contact housing with contact locking mechanism use if required: connection piece level sensor |
1 | 4B0 973 712 A | - | ||
25 | grommet for contact housing: |
1 | 6N0 906 102 | - | ||
26 | flat contact housing with contact locking mechanism connection piece brake pad wear display shock absorbers |
X 1 1 |
1J0 973 702 | 3 | ||
27 | flat contact housing with gasket if required use also item: connection piece tyre pressure sensor |
1 | 8T0 973 702 | - | ||
27 | flat contact housing with contact locking mechanism connection piece tyre pressure sensor |
1 | 6E0 973 702 | - | ||
28 | removable housing for aerial female connector to use for: connection piece aerial amplifier aerial cable |
1 | 4L0 035 576 K | - | ||
29 | flat contact housing with contact locking mechanism connection piece tail light |
1 | 4H0 973 713 | - | ||
29 | flat contact housing connection piece tail light |
1 | 5N1 973 206 | - | ||
29A | flat contact housing with contact locking mechanism use if required: connection piece additional brake light coupling element diagnosis pump for fuel system |
X 1 1 |
1J0 973 803 | 1 | ||
29B | protective cap for contact housing: |
1 | 3C0 971 921 | - | ||
29C | bracket for contact housing: |
1 | 3D0 971 830 J | - | ||
29D | bracket for contact housing: |
1 | 3D0 971 830 K | - | ||
30 | flat contact housing connection piece hydraulic system for actuating convertible roof |
1 | 1J0 972 752 | - | ||
40 | individual parts area: see illustration: |