№ | Name | Ext. inf. | A* | Use of | Part number | A |
---|---|---|---|---|---|---|
onboard supply control unit central control unit for convenience system D >> - MJ 2011 diagnosis interface for data bus (gateway) D >> - MJ 2009 |
||||||
onboard supply control unit central control unit for convenience system |
||||||
1 | onboard supply control unit for veh. with mech. height adjustable steering column hardware: PR-2C5
|
PR-2C5 | 1 | 4F0 910 279 N | - | |
- | *only possible to determine *the fitted part number by *reading it using the *diagnostics tester. |
|||||
(1) | onboard supply control unit for veh. with mech. height adjustable steering column PR-2C5
|
PR-2C5 | 1 | 4F0 910 279 AF | - | |
(1) | onboard supply control unit for vehicles with electic height-adjust. steering column PR-2C7
|
PR-2C7 | 1 | 4F0 910 279 AE | - | |
(1) | onboard supply control unit for vehicles with electic height-adjust. steering column hardware: PR-2C7
|
PR-2C7 | 1 | 4F0 910 279 M | - | |
(1) | onboard supply control unit for vehicles with electic height-adjust. steering column PR-FN0,FN1
|
PR-FN0,FN1 | 1 | 4F0 910 279 AE | - | |
(1) | onboard supply control unit for vehicles with electic height-adjust. steering column hardware: PR-FN0,FN1
|
PR-FN0,FN1 | 1 | 4F0 910 279 M | - | |
2 | onboard supply control unit | 1 | 4F0 907 280 B | - | ||
3 | central control unit for convenience system |
1 | 4F0 910 289 N | - | ||
(3) | central control unit for convenience system |
1 | 4F0 910 289 K | - | ||
4 | flat contact housing with contact locking mechanism |
1 | 8E0 972 710 | - | ||
5 | flat contact housing with cap locking mechanism |
1 | 8L0 972 977 | - | ||
7 | flat contact housing with contact locking mechanism |
X | 4B0 973 721 | - | ||
8 | flat contact housing with contact locking mechanism |
1 | 1J0 962 615 B | - | ||
9 | flat contact housing with cap |
1 | 038 906 379 B | - | ||
10 | retainer for control unit see illustration: |
1 | ||||
diagnosis interface for data bus (gateway) D >> - MJ 2009 |
||||||
15 | diagnosis interface for data bus (gateway) F >> 4F-9N045 000* F >> 4F-9Y000 225* PR-7Y0+8N6+ 8T0,8T1 |
PR-7Y0+8N6+ 8T0,8T1 |
1 |
4F0 907 468 F | - | |
15 | diagnosis interface for data bus (gateway) PR-7Y0+8N6+
8T0,8T1 |
PR-7Y0+8N6+ 8T0,8T1 |
1 | 4F0 907 468 M | - | |
15 | diagnosis interface for data bus (gateway) PR-7Y0+8N6+
8T0,8T1 |
PR-7Y0+8N6+ 8T0,8T1 |
1 | 4F0 907 468 K | - | |
(15) | diagnosis interface for data bus (gateway) F >> 4F-9N045 000* F >> 4F-9Y000 225* PR-7Y1,7Y2, 7Y3+8N6+8T0, 8T1 |
PR-7Y1,7Y2, 7Y3+8N6+8T0, 8T1 |
1 |
4F0 907 468 G | - | |
(15) | diagnosis interface for data bus (gateway) PR-7Y1,7Y2,
7Y3+8N6+8T0 8T1 |
PR-7Y1,7Y2, 7Y3+8N6+8T0 8T1 |
1 | 4F0 907 468 N | - | |
(15) | diagnosis interface for data bus (gateway) PR-7Y1,7Y2,
7Y3+8N6+8T0 8T1 |
PR-7Y1,7Y2, 7Y3+8N6+8T0 8T1 |
1 | 4F0 907 468 L | - | |
(15) | diagnosis interface for data bus (gateway) F >> 4F-9N045 000* F >> 4F-9Y000 225* PR-8N6+8T4 |
PR-8N6+8T4 |
1 |
4F0 907 468 G | - | |
(15) | diagnosis interface for data bus (gateway) PR-8N6+8T4
|
PR-8N6+8T4 | 1 | 4F0 907 468 N | - | |
(15) | diagnosis interface for data bus (gateway) PR-8N6+8T4
|
PR-8N6+8T4 | 1 | 4F0 907 468 L | - | |
(15) | diagnosis interface for data bus (gateway) F >> 4F-9N045 000* F >> 4F-9Y000 225* PR-8N7 |
PR-8N7 |
1 |
4F0 907 468 G | - | |
(15) | diagnosis interface for data bus (gateway) PR-8N7
|
PR-8N7 | 1 | 4F0 907 468 N | - | |
(15) | diagnosis interface for data bus (gateway) PR-8N7
|
PR-8N7 | 1 | 4F0 907 468 L | - | |
16 | flat contact housing with contact locking mechanism also to be used for: cable output: |
1 | 8E0 972 420 | - | ||
(16) | flat contact housing with contact locking mechanism cable output: |
1 | 8E0 972 420 B | - | ||
(16) | flat contact housing with contact locking mechanism cable output: |
1 | 8E0 972 420 C | - | ||
(16) | housing fibre optic wave conductor see illustration, item: |
|||||
17 | fillister head bolt (combi.) | 2 | N 907 290 02 | - |