№ | Name | Ext. inf. | A* | Use of | Part number |
---|---|---|---|---|---|
wiring harness for interior | |||||
- | wiring harness for interior | 1 | 6Z3 971 180 G | ||
individual parts | |||||
- | * corrug. tubes, t-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * electrical * connecting elements |
||||
- | * aerial lead conn. * housing see special * catalogue: electrical * connecting elements |
||||
- | the connector housing is found in the individual position of the component. see gen. prts. bulletin (9-87) |
||||
- | flat contact housing with contact locking mechanism |
1 | 8E0 972 112 A | ||
- | flat contact housing with contact locking mechanism cable outl.: |
1 | 8E0 972 416 A | ||
- | flat contact housing with contact locking mechanism also to be used for: cable output: |
1 | 8E0 972 420 | ||
- | flat contact housing with cap locking mechanism |
1 | 1J0 972 977 D | ||
- | flat contact housing with cap locking mechanism |
1 | 1J0 972 977 | ||
- | flat contact housing with cap locking mechanism cable output: |
1 | 1J0 972 977 G | ||
- | flat connector housing control unit for airbag |
1 | 8K0 973 125 A | ||
- | flat contact housing with contact locking mechanism |
1 | 8E0 972 126 | ||
- | flat contact housing with contact locking mechanism cable output: |
1 | 5Q0 972 718 A | ||
- | flat connector housing | X | 4B0 971 978 C | ||
- | flat contact housing | X | 4D0 971 636 D | ||
- | flat contact housing with additional contact lock and additional connector housing mountings |
1 | 3B7 035 444 A | ||
- | flat contact housing with contact locking mechanism |
X | 1K0 971 980 | ||
- | flat contact housing with contact locking mechanism |
X | 8E0 971 980 | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 972 930 A | ||
- | flat contact housing with contact locking mechanism |
1 | 1K0 972 928 | ||
- | flat contact housing with contact locking mechanism |
1 | 1K0 971 975 | ||
- | flat contact housing with cap locking mechanism |
1 | 7M3 972 726 B | ||
- | flat contact housing | 1 | 8W0 971 832 | ||
- | flat contact housing with contact locking mechanism |
1 | 4B0 972 623 | ||
- | flat connector housing control unit for electronic stabilisation program -esp- use if required: 5Q0 971 904 |
5Q0 971 904 |
1 | 8V0 998 623 | |
- | flat contact housing with contact locking mechanism |
1 | 4E0 972 133 | ||
- | flat contact housing with contact locking mechanism |
1 | 3B7 035 447 | ||
- | flat contact housing with contact locking mechanism |
1 | 3C0 906 385 | ||
- | double relay carrier | 1 | 4H0 937 529 | ||
- | fuse socket | 1 | 6R0 937 548 C | ||
- | flat contact housing with gasket |
1 | 8T0 973 702 | ||
- | flat contact housing | 1 | 038 973 721 | ||
- | cable guide | 1 | 6Z3 971 445 | ||
- | flat contact housing with contact locking mechanism |
1 | 3C0 973 737 | ||
- | flat contact housing with contact locking mechanism injection valve |
1 | 07P 973 702 | ||
- | flat connector housing with contact locking mechanism |
1 | 4D0 971 992 | ||
- | flat contact housing | 1 | 4H0 973 702 A | ||
- | flat contact housing with contact locking mechanism |
1 | 8K0 973 702 | ||
- | flat contact housing with contact locking mechanism |
1 | 8K0 973 702 A | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 972 923 | ||
- | flat contact housing with contact locking mechanism |
1 | 8K0 973 703 | ||
- | flat contact housing | 1 | 8K0 973 754 | ||
- | flat contact housing with contact locking mechanism |
1 | 8K0 973 704 | ||
- | flat contact housing | 1 | 8K0 973 724 | ||
- | flat contact housing | 2 | 1J0 973 733 | ||
- | flat contact housing with contact locking mechanism |
1 | 1K0 937 702 D | ||
- | flat contact housing with contact locking mechanism |
1 | 1K0 937 702 E | ||
- | flat contact housing with contact locking mechanism |
1 | 1K0 937 702 F | ||
- | flat contact housing with gasket |
X | 357 972 752 | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 973 737 | ||
- | flat contact housing with contact locking mechanism |
1 | 6X0 973 717 A | ||
- | flat contact housing with contact locking mechanism |
1 | 1K0 973 213 | ||
- | flat contact housing with gasket |
1 | 1J0 906 379 B | ||
- | flat contact housing with contact locking mechanism also to be used for: |
1 | 6X0 973 722 G | ||
- | flat contact housing with retainer guide |
1 | 6R0 971 959 A | ||
- | flat contact housing | 1 | 5K0 973 323 | ||
- | flat contact housing | 1 | 1H0 972 702 A | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 973 119 | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 973 722 | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 973 722 A | ||
- | flat contact housing with contact locking mechanism |
1 | 7M0 973 202 | ||
- | flat contact housing with contact locking mechanism |
1 | 4H0 973 703 | ||
- | flat contact housing with contact locking mechanism |
1 | 1K0 972 772 | ||
- | flat contact housing with contact locking mechanism |
1 | 4H0 973 704 | ||
- | relay plate | 1 | 3C0 973 721 | ||
- | flat contact housing | 1 | 1J0 906 234 | ||
- | flat contact housing | 1 | 8R0 973 605 | ||
- | flat contact housing | 1 | 6N0 973 755 | ||
- | flat contact housing | 1 | 1J0 972 755 | ||
- | flat contact housing with contact locking mechanism |
1 | 4F0 973 706 | ||
- | flat connector housing with contact locking mechanism |
X | 3B0 972 712 | ||
- | flat contact housing | 1 | 1J0 973 332 | ||
- | bracket for connector housing 6R0 973 735
1J0 973 835 |
6R0 973 735 1J0 973 835 |
1 | 1J0 906 029 A | |
- | cable tie with holder for weld pin: 5X200
5MM |
5X200 5MM |
X | 3D0 971 838 A | |
- | cable holder for bridge strength: plug socket: 1-3MM |
1-3MM |
X | 1T0 971 930 D | |
- | cable holder b-pillar |
X | 3B0 971 848 F | ||
- | cable holder hole/sheet metal thickness: 6,5/0,6-3,0 |
6,5/0,6-3,0 |
X | 4B0 971 848 | |
- | cable holder | 1 | 7L6 971 741 A | ||
- | removable housing for aerial female connector to use for: use if required aerial wire adapter: 000 098 703 |
000 098 703 |
X | 6Q0 035 576 K | |
- | flat contact housing with contact locking mechanism |
1 | 8K0 973 706 | ||
- | cable ties toothed quadrant hole/sheet metal thickness: 4,6X193MM
6,5/0,3-3,0MM |
4,6X193MM 6,5/0,3-3,0MM |
1 | 3W0 971 838 | |
- | flat contact housing with contact locking mechanism |
1 | 1J0 973 702 | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 973 704 | ||
- | flat contact housing | 1 | 1J0 973 724 | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 973 726 | ||
- | flat contact housing | 1 | 6R0 973 735 | ||
- | fuse holder | 1 | 3A0 937 501 A | ||
- | relay plate | X | 443 937 527 | ||
- | relay plate | X | 4H0 937 527 | ||
- | relay plate | 1 | 4H0 937 528 | ||
- | grommet | 1 | 7H0 941 389 H | ||
- | fuse holder | 1 X |
7H0 937 617 | ||
- | cable ties hole/sheet metal thickness: 6,3-7/0,7-7MM |
6,3-7/0,7-7MM |
X | 3R0 971 848 A | |
- | flat contact housing cigarette lighter |
1 | 1J0 919 321 | ||
- | flat contact housing with contact locking mechanism |
1 | 4H0 973 712 | ||
- | flat contact housing with contact locking mechanism |
1 | 4H0 973 713 D | ||
- | flat contact housing with contact locking mechanism |
1 | 4H0 973 713 | ||
- | flat contact housing with contact locking mechanism |
1 | 4H0 973 714 | ||
- | flat contact housing with contact locking mechanism |
1 | 4H0 973 717 | ||
- | flat contact housing with contact locking mechanism |
1 | 8K0 973 703 | ||
- | grommet 8,2X40
|
8,2X40 | 1 | 1J0 906 102 | |
- | grommet | 1 | 7M0 971 840 C | ||
- | guide piece | 1 | 1T0 972 822 F | ||
- | cable holder heat exchanger for high-voltage battery also use: DA .001.730.A2 |
DA .001.730.A2 |
1 | 6Z3 971 457 C | |
- | 2-pack epoxy adhesive body rep. -aluminium- |
1 | DA 001 730 A2 |