№ | Name | Ext. inf. | A* | Use of | Part number |
---|---|---|---|---|---|
diy wiring sets | |||||
1 | electric cable in coils of 50m 'order unit 50' D0,5
|
D0,5 | * | N 037 006 6 | |
1 | electric line in 50 m rolls. high-temp. resistant 'order quantity 50' FL2G-0,5
|
FL2G-0,5 | * | N 902 861 10 | |
1 | electric cable in coils of 50m 'order unit 50' D1,0
|
D1,0 | * | N 037 021 1 | |
1 | electric line in 50 m rolls. high-temp. resistant 'order quantity 50' FL2G-1
|
FL2G-1 | * | N 101 639 04 | |
1 | electric wiring in rolls of 50m.high-temperature, fuel and lubricant stocks. 'order qty. 50' W1,5
|
W1,5 | * | N 901 726 02 | |
1 | electric cable in coils of 50m 'order unit 50' W2,5
|
W2,5 | * | N 037 041 1 | |
1 | flat band wire in rolls of 50 m 'order quantity 50' 2X2,5
|
2X2,5 | * | N 904 206 01 | |
1 | electric cable in coils of 50m 'order unit 50' W4,0
|
W4,0 | * | N 018 250 3 | |
1 | electric cable in coils of 50m 'order unit 50' W6,0
|
W6,0 | * | N 018 463 3 | |
1 | electric line in 50 m rolls. high-temp. resistant 'order quantity 50' SH6,0
|
SH6,0 | * | N 903 209 02 | |
1 | Widerstandsleitung (Gruen) In Rollen zu 50m 'bestelleinheit 50' 14 OHM/M
|
14 OHM/M | * | N 900 120 08 | |
1 | resistance cable (transparent/ green) in coils of 25m 'order unit 25' 0,5 OHM/M
|
0,5 OHM/M | * | N 900 120 04 | |
1 | Widerstandsleitung (Transpa- Rent/Schwarz) in Rollen zu 50m 'bestelleinheit 50' 0,27 OHM/M
|
0,27 OHM/M | * | N 900 120 05 | |
2 | insulating hose in 5 m reels 'order quantity 5' 4X0,5
|
4X0,5 | * | N 018 004 1 | |
2 | insulating hose in 5 m reels 'order quantity 5' W7X0,6
|
W7X0,6 | * | N 018 007 4 | |
2 | insulating hose in rolls of 5m high temperature resistant 'order unit 5' 11X0,7 |
11X0,7 |
* | N 900 183 01 | |
2 | insulating hose in 5 m reels 'order quantity 5' 14X0,8
|
14X0,8 | * | N 018 014 1 | |
2 | insulating tape 0,15X19X10000
|
0,15X19X10000 | 1 | N 103 113 04 | |
* corrug. tubes, t-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * electrical * connecting elements |
|||||
1 | wire set width indicat. lamp F >> 21-PH019 000 ============================== |
||||
- | flat connector housing | 2 | 161 971 976 A | ||
- | fuse box for flat fuses |
1 | 161 937 501 | ||
1 | wire set width indicat. lamp F 21-PH020 001>> ============================== |
||||
- | flat contact housing | 1 | 3A0 972 751 H | ||
- | flat contact housing | 2 | 191 972 701 | ||
- | grommet 20/4
|
20/4 | 1 | 411 941 189 | |
2 | wire set switch roof ventilador ============================== |
||||
- | round connector housing F >> 21-PH019 000 |
1 |
171 971 998 A | ||
- | flat contact housing F 21-PH020 001>> |
1 |
1H0 973 131 A | ||
- | flat contact housing F 21-PH020 001>> |
1 |
1J0 973 332 | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | fuse box for flat fuses |
1 | 1H0 937 530 | ||
- | flat fuse 19/2x5 | 1 | N 017 131 11 | ||
- | flat contact housing F 21-PH020 001>> |
1 |
111 971 921 B | ||
- | flat contact housing F 21-PH020 001>> |
1 |
3A0 972 751 H | ||
2 | adapter cable loom roof ventilador ============================== |
||||
- | flat contact housing | 1 | 161 971 989 C | ||
- | flat contact housing F 28-M-000 001>> |
1 |
191 972 753 | ||
- | rd. connector sleeve housing F >> 21-PH015 000* |
1 |
171 971 999 A | ||
- | flat contact housing F 21-PH015 001>>* |
1 |
1H0 973 121 C | ||
3 | wire set socket ============================== |
||||
- | flat connector housing | 1 | 161 971 988 C | ||
- | flat contact housing | 2 | 161 971 989 C | ||
4 | wire set warning lamp ============================== 4X4
|
4X4 | |||
- | round connector housing F >> 21-PH019 000 |
1 |
171 971 998 B | ||
- | flat connector housing F 21-PH020 001>> |
1 |
191 972 713 | ||
4 | wire set differential lock, engageable ============================== 4X4
|
4X4 | |||
- | grommet 20/4
|
20/4 | 1 | 411 941 189 | |
- | protective cap 18,5X5
|
18,5X5 | 2 | 411 941 539 | |
- | protective cap 18,5X8
|
18,5X8 | 1 | 251 911 521 | |
- | rd. connector sleeve housing F >> 21-PH019 000 |
1 |
171 971 999 B | ||
- | flat contact housing F 21-PH020 001>> |
1 |
191 972 703 | ||
- | flat contact housing F 21-PH020 001>> |
1 |
1J0 972 924 | ||
- | flat contact housing F 21-PH020 001>> |
1 |
3A0 972 751 H | ||
4 | wire set selector lever ============================== 4X4
|
4X4 | |||
- | flat contact housing | 1 | 191 906 231 A | ||
- | flat contact housing | 1 | 111 971 921 B | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | flat contact housing F 21-PH020 001>> |
1 |
701 906 231 | ||
5 | tachograph wiring harness ============================== |
||||
- | flat contact housing | 1 | ZBA 971 838 | ||
- | flat contact housing | 1 | 803 905 897 | ||
- | flat connector housing F >> 28-L-030 000 |
1 |
161 971 988 C | ||
- | flat contact housing F >> 28-L-030 000 |
1 |
161 971 989 C | ||
- | flat contact housing F 28-M-000 001>> |
1 |
1J0 972 753 | ||
- | flat contact housing F 28-M-000 001>> |
1 |
191 972 763 | ||
5 | tachograph wiring harness ============================== |
||||
- | flat connector housing | 1 | 281 957 897 E | ||
- | flat contact housing | 1 | 111 971 921 B | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | flat connector housing F >> 28-L-030 000 |
1 |
161 971 988 C | ||
- | flat contact housing F >> 28-L-030 000 |
1 |
161 971 989 C | ||
- | flat contact housing F 28-M-000 001>> |
1 |
1J0 972 753 | ||
- | flat contact housing F 28-M-000 001>> |
1 |
191 972 763 | ||
6 | wiring harness for number plate light ============================== |
||||
- | grommet F >> 21-PH019 000 F 21-PH020 001>> 12,5
|
12,5 | 2 1 |
171 971 913 | |
- | grommet F 21-PH020 001>> 22/3
|
22/3 | 1 |
803 611 751 | |
- | flat contact housing with contact locking mechanism F 21-PH020 001>> |
1 |
1J0 972 923 | ||
- | flat contact housing with contact locking mechanism F 21-PH020 001>> |
1 |
1J0 972 702 | ||
- | flat contact housing F 21-PH020 001>> |
1 |
191 972 702 | ||
7 | single wire heated rear window ============================== |
||||
- | flat contact housing also use: 000 979 222 |
000 979 222 |
2 X |
1H0 971 921 A | |
- | 1 set single wires each with 2 contacts, in bag of 5 'order qty. 5' 2,5
|
2,5 | X | 000 979 222 | |
8 | harness for interior light ============================== |
||||
- | flat contact housing F 21-PH020 001>> |
2 | 191 906 231 B | ||
- | ground connector F 21-PH020 001>> 6,3
|
6,3 | 1 | 191 971 519 | |
- | flat contact housing F 21-PH020 001>> |
1 | 1H0 973 121 C | ||
- | flat connector housing F 21-PH020 001>> |
2 | 191 972 761 | ||
- | flat contact housing also use: 000 979 222 |
000 979 222 |
2 X |
1H0 971 921 A | |
- | 1 set single wires each with 2 contacts, in bag of 5 'order qty. 5' 2,5
|
2,5 | X | 000 979 222 | |
- | flat contact housing | 2 | 111 971 921 B | ||
- | flat connector housing F >> 28-L-030 000 |
1 |
161 971 976 A | ||
- | flat contact housing F 28-M-000 001>>F 21-PH019 000 |
1 |
191 972 701 | ||
- | flat contact housing F 21-PH020 001>> |
1 | 3A0 972 751 H | ||
8 | harness for interior light ============================== |
||||
- | flat contact housing | 3 | 111 971 921 B | ||
- | flat connector housing F >> 21-PH019 000 |
1 |
191 972 711 | ||
- | flat contact housing F 21-PH020 001>> |
1 |
1J0 973 332 | ||
9 | wiring harness for seat belt warning system ============================== |
||||
- | relay plate | 1 | 531 941 845 | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | round connector housing | 1 | 171 971 998 A | ||
- | flat contact housing F 21-PH020 001>> |
1 |
701 906 231 | ||
10 | wiring harness for fog lamps rear fog light F >> 28-L-030 000 ============================== |
||||
- | flat fuse 19/2x5 | N 017 131 11 | |||
- | fuse box for flat fuses |
1 | 1H0 937 530 | ||
- | relay plate | 1 | 161 937 501 B | ||
- | flat contact housing | 1 | 171 941 599 | ||
- | flat connector housing | 3 | 161 971 976 A | ||
- | flat connector housing | 1 | 161 971 988 C | ||
- | flat contact housing | 1 | 161 971 989 C | ||
10 | wiring harness for fog lamps F 28-M-000 001>> 21-PH-019 000 ============================== |
||||
- | relay plate | 1 | 161 937 501 B | ||
- | flat contact housing | 2 | 161 971 990 A | ||
- | flat contact housing | 1 | 111 971 921 B | ||
- | flat contact housing | 1 | 191 972 751 | ||
- | flat connector housing | 1 | 191 972 761 | ||
10 | wiring harness for fog lamps F 21-PH020 001>> ============================== |
||||
- | relay plate | 1 | 161 937 501 B | ||
- | flat connector housing | 1 | 191 972 761 | ||
- | flat contact housing | 1 | 111 971 921 B | ||
- | flat contact housing with contact locking mechanism |
2 | 1J0 972 923 | ||
- | flat contact housing with contact locking mechanism |
2 | 1J0 972 702 | ||
- | flat contact housing | 2 | 191 972 702 | ||
- | flat contact housing | 1 | 191 972 751 | ||
- | flat contact housing | 1 | 3A0 972 751 H | ||
- | flat contact housing F >> 21-PH019 000 |
1 | 1H0 972 701 | ||
- | flat contact housing F 21-PH020 001>> |
1 | 701 906 231 | ||
- | flat contact housing | 1 | 701 906 231 | ||
10 | adapter cable loom rear fog light F 28-M-000 001>> ============================== |
||||
- | flat connector housing F >> 21-PH019 000 |
2 |
161 971 976 A | ||
- | flat contact housing F >> 21-PH019 000 |
2 |
161 971 990 A | ||
- | flat contact housing with gasket F 21-PH020 001>> |
1 |
357 972 752 | ||
- | flat connector housing F 21-PH020 001>> |
1 |
357 972 762 | ||
11 | wire set emergency siren system relay ============================== police
|
police | |||
- | flat fuse 19/2x5 | 1 | N 017 131 11 | ||
- | flat fuse 19/2x5 AMP |
AMP |
1 | N 017 131 12 | |
- | flat contact housing | 1 | ZBA 971 838 | ||
- | flat contact housing | 1 | 803 905 897 | ||
- | fuse box for flat fuses |
2 | 1H0 937 530 | ||
- | flat contact housing | 7 | 111 971 921 B | ||
- | flat contact housing | 1 | 803 971 831 | ||
- | flat connector housing F >> 21-PH019 000 F 21-PH020 001>> |
2 1 |
161 971 976 A | ||
- | flat contact housing F >> 21-PH019 000 |
1 |
161 971 990 A | ||
- | flat connector housing F >> 21-PH019 000 |
X |
191 972 711 | ||
- | flat connector housing F.21-PH020 001>> also use: 161 971 990 A |
161 971 990 A |
1 1 |
161 971 976 A | |
- | flat contact housing F 21-PH020 001>> |
1 |
701 906 231 | ||
11 | wire set rotating warning light emergency siren system relay ============================== police
|
police | |||
- | flat fuse 19/2x5 | 1 | N 017 131 11 | ||
- | flat fuse 19/2x5 AMP |
AMP |
1 | N 017 131 12 | |
- | flat connector housing for vehicles with emergency siren system relay electronic |
1 | 281 957 897 A | ||
- | flat contact housing | 2 | ZBA 971 838 | ||
- | flat contact housing | 2 | 803 905 897 | ||
- | fuse box for flat fuses |
2 | 1H0 937 530 | ||
- | bracket insert sleeve housing | 6 | 211 971 921 | ||
- | flat contact housing | 1 | 111 971 921 B | ||
- | flat contact housing | 1 | 803 971 831 | ||
- | flat connector housing | 2 | 161 971 976 A | ||
- | flat contact housing F >> 21-PH019 000 |
1 |
161 971 990 A | ||
- | flat connector housing F >> 21-PH019 000 |
2 |
191 972 711 | ||
- | flat connector housing F.21-PH020 001>> also use: 161 971 990 A |
161 971 990 A |
1 1 |
161 971 976 A | |
- | flat contact housing F 21-PH020 001>> |
1 |
3A0 972 751 H | ||
11 | wire set rotating warning light ============================== police
|
police | |||
- | relay plate | 1 | 161 937 501 B | ||
- | fuse box for flat fuses |
1 | 1H0 937 530 | ||
- | flat fuse 19/2x5 | 1 | N 017 131 12 | ||
- | flat contact housing | 2 | 111 971 921 B | ||
- | flat contact housing F 21-PH020 001>> |
1 |
701 906 231 | ||
12 | wire set analogue clock ============================== |
||||
- | bracket insert sleeve housing | 1 | 211 971 921 | ||
- | flat contact housing | 1 | 111 971 921 B | ||
- | flat connector housing F >> 28-L-030 000 |
1 |
161 971 988 C | ||
- | flat contact housing F >> 28-L-030 000 |
1 |
161 971 989 C | ||
- | flat contact housing F 28-M-000 001>> |
1 |
1J0 972 753 | ||
- | flat contact housing F 28-M-000 001>> |
1 |
191 972 763 | ||
12 | wire set socket ============================== |
||||
- | flat contact housing | 1 | 191 972 763 | ||
- | flat contact housing | 1 | 191 919 321 | ||
13 | wire set additional coolant pump ============================== S706
|
S706 | |||
13 | no replacement part | 1 | 281 971 764 C | ||
- | relay plate | 1 | 531 941 845 | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | flat contact housing | 2 | 111 971 921 B | ||
- | flat contact housing | 1 | 161 971 990 A | ||
- | flat contact housing | 1 | 171 971 990 | ||
- | rd. connector sleeve housing | 1 | 171 971 999 A | ||
14 | wire set thermal switch F >> 28-M-008 000* ============================== S706 |
S706 |
|||
14 | no replacement part | 281 971 375 | |||
- | flat contact housing with gasket |
1 | 443 906 232 | ||
- | grommet 16,5
|
16,5 | 1 | 111 971 911 A | |
- | flat contact housing | 2 | 111 971 921 B | ||
- | round connector housing | 1 | 171 971 998 A | ||
- | grommet 12,5X31
|
12,5X31 | 1 | 810 972 525 | |
15 | wiring light for seat heating ============================== |
||||
- | fuse box for flat fuses |
1 | 1H0 937 530 | ||
- | relay plate | 1 | 161 937 501 B | ||
- | flat contact housing | 1 | 321 971 946 | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | flat connector housing F >> 28-L-030 000 |
1 |
161 971 988 C | ||
- | flat contact housing F >> 28-L-030 000 |
1 |
161 971 989 C | ||
- | round connector housing | 1 | 171 971 998 E | ||
- | flat contact housing F 28-M-000 001>> 21-PH019 000 |
1 |
1J0 972 753 | ||
- | flat contact housing F 28-M-000 001>> 21-PH019 000 |
1 |
191 972 763 | ||
- | flat fuse 19/2x5 | 1 | N 017 131 12 | ||
- | flat contact housing F 21-PH020 001>> |
1 |
701 906 231 | ||
- | flat contact housing F 21-PH020 001>> |
1 | 191 972 701 | ||
15 | wiring light for seat heating ============================== |
||||
- | flat contact housing | 1 | 161 971 990 A | ||
- | round connector housing | 1 | 171 971 998 A | ||
- | round connector housing | 1 | 171 971 998 E | ||
16 | wire set water level switch ============================== |
||||
- | relay plate | 1 | 161 937 501 B | ||
- | flat contact housing | 1 | 111 971 921 B | ||
- | rd. connector sleeve housing | 1 | 171 971 999 A | ||
17 | wiring set for starter ============================== |
||||
- | relay plate
DIGIFANT
|
1 | DIGIFANT | 251 937 501 | |
- | relay plate
diesel eng.
|
1 | diesel eng. | 161 937 501 B | |
- | flat contact housing
DIGIFANT
|
1 | DIGIFANT | 171 971 934 | |
- | flat connector housing
diesel eng.
|
1 | diesel eng. | 161 971 976 A | |
- | flat contact housing
diesel eng.
|
1 | diesel eng. | 161 971 990 A | |
- | flat contact housing
diesel eng.
|
1 | diesel eng. | 171 971 990 | |
- | flat contact housing F 21-PH020 001>> diesel eng. |
1 |
diesel eng. |
701 906 231 | |
18 | wiring harness for headlight washer system F >> 21-PH019 000 ============================== |
||||
- | relay plate | 1 | 161 937 501 B | ||
- | flat contact housing | 2 | 111 971 921 B | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | flat contact housing | 1 | 161 971 989 C | ||
18 | wiring harness for headlight washer system F 21-PH020 001>> ============================== |
||||
- | flat contact housing | 1 | 161 971 989 C | ||
- | relay plate | 1 | 161 937 501 B | ||
- | flat contact housing | 2 | 111 971 921 B | ||
- | flat connector housing for models with day driving headlights |
1 | 191 972 711 | ||
- | flat contact housing | 1 | 3A0 972 751 H | ||
- | flat contact housing | 1 | 701 906 231 | ||
- | flat contact housing | 1 | 171 971 990 | ||
19 | wiring harness for fuel pump ============================== |
||||
- | grommet F >> 21-N-012 000* 18X20,5
|
18X20,5 | 1 |
443 906 102 B | |
- | flat contact housing with gasket F >> 21-N-120 000* |
1 |
191 906 232 A | ||
- | single wiring seal for wire cross section: 5,6X7,8
1,5 |
5,6X7,8 1,5 |
2 | 357 972 741 A | |
- | single wiring seal for wire cross section: F 21-N-012 001>>* 9,0X7,8
1,5 |
9,0X7,8 1,5 |
2 |
357 972 742 A | |
- | flat contact housing with gasket |
1 | 357 972 752 | ||
- | flat contact housing with gasket F 21-N-012 001>>* |
1 |
357 972 772 | ||
20 | wire set operating hour meter ============================== |
||||
- | flat contact housing | 1 | 111 971 921 B | ||
- | flat connector housing | 1 | 161 971 976 A | ||
- | flat contact housing | 1 | 161 971 989 C | ||
- | flat contact housing F 21-PH020 001>> |
1 |
701 906 231 | ||
21 | wire set high volume horn ============================== police
|
police | |||
- | protective cap 2X10
|
2X10 | 4 | 191 919 083 | |
- | grommet 20/4
|
20/4 | 1 | 411 941 189 | |
- | grommet F >> 21-PH019 000 16,5
|
16,5 | 2 |
111 971 911 A | |
- | grommet F 21-PH020 001>> 23,5/6
|
23,5/6 | 2 |
021 119 569 A | |
- | flat contact housing F 21-PH020 001>> |
1 |
191 972 701 | ||
- | flat contact housing F 21-PH020 001>> |
1 |
3A0 972 751 H | ||
22 | single wire earth line for turn signal or socket ============================== |
||||
- | flat contact housing | 1 | 3A0 972 751 H | ||
- | flat contact housing connection piece ground connector turn signal indicator |
1 | 111 971 921 B | ||
23 | single wire handbrake control lamp ============================== |
||||
- | flat contact housing | 1 | 191 972 701 | ||
24 | wiring harness for diagnosis ============================== |
||||
- | flat connector housing | 2 | 191 972 711 | ||
- | flat contact housing with contact locking mechanism |
1 | 443 972 577 E | ||
24 | wiring harness for voltage supply ============================== DIAGNOSE
|
DIAGNOSE | |||
- | flat contact housing with contact locking mechanism |
1 | 443 972 580 | ||
- | flat connector housing | 1 | 191 972 711 | ||
- | flat contact housing | 1 | 3A0 972 751 H | ||
25 | adapter cable loom cigarette lighter analogue clock or tachograph F 21-PH020 001>> ============================== |
||||
- | flat connector housing | 1 | 191 972 711 | ||
- | flat contact housing | 1 | 1J0 972 753 | ||
- | flat contact housing | 1 | 191 972 763 | ||
- | flat contact housing | 1 | 357 035 447 | ||
26 | wiring harness for turn signal roof ============================== |
||||
- | flat connector housing | 2 | 161 971 976 A | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 972 923 | ||
- | flat contact housing with contact locking mechanism |
1 | 1J0 972 702 | ||
- | flat contact housing | 1 | 191 972 702 | ||
27 | adapter cable loom for diagnostic plug ============================== |
||||
- | flat contact housing | 1 | 1H0 972 695 | ||
- | flat contact housing | 1 | 1H0 972 701 | ||
- | flat connector housing | 1 | 191 972 711 | ||
- | flat contact housing | 1 | 3A0 972 751 H |