№ | Name | Ext. inf. | A* | Use of | Part number |
---|---|---|---|---|---|
individual parts wiring harness for interior area: |
|||||
individual parts (general notes) area: dash panel tunnel |
dash panel tunnel |
||||
- | the connector housing is found in the individual position of the component see parts bulletin: (9-87) |
(9-87) |
|||
- | * corrug. tubes, t-pieces, * clips, holders, grommets, * cable ties, insulating * hose, wiring, * single wires and seals * see special catalogue: * electrical * connecting elements |
||||
- | list of uses coupling st. connector housing see illustration: 971-079 |
971-079 |
|||
- | wiring harness for interior see illustration: 971-080 |
971-080 |
|||
- | cable guide relay plate support see illustration: 971-080 |
971-080 |
|||
- | wiring harness for speed sensor see illustration: 927-000 |
927-000 |
|||
- | adapter aerial wire see catalogue: |
||||
connector housing 1 pin
|
1 pin | ||||
1 | removable housing for aerial bracket female connector to use for: |
X | 4E0 035 675 K | ||
(1) | removable housing for aerial pin connector to use for: |
X | 6Q0 035 575 K | ||
(1) | removable housing for aerial female connector to use for: |
X | 6Q0 035 576 K | ||
connector housing 2 pin
|
2 pin | ||||
2 | flat contact housing with contact locking mechanism |
X | 4B0 971 832 | ||
(2) | flat connector housing | X | 1J0 971 972 | ||
(2) | flat contact housing with contact locking mechanism |
X | 4B0 972 623 | ||
(2) | removable housing for aerial bracket female connector to use for: |
X | 4E0 035 672 K | ||
(2) | flat connector fibre optic wave conductor |
X | 4E0 973 702 | ||
(2) | flat contact housing with contact locking mechanism use if required: 3C0 971 921 |
3C0 971 921 |
X | 1J0 973 722 A | |
(2) | protective cap | X | 3C0 971 921 | ||
connector housing 3 pin
|
3 pin | ||||
3 | flat contact housing | X | 1K0 972 723 A | ||
(3) | flatcontact housing with cable | X | 3C8 971 582 | ||
(3) | flat contact housing | X | 4G0 919 321 | ||
(3) | flat contact housing | X | 1J0 919 321 | ||
connector housing 4 pin
|
4 pin | ||||
4 | flat contact housing | X | 4H0 972 133 | ||
(4) | flat contact housing | X | 8K0 973 754 | ||
connector housing 6 pin
|
6 pin | ||||
5 | flat contact housing also to be used for: |
X | 4D0 971 636 | ||
(5) | flat contact housing with contact locking mechanism |
X | 1K0 973 706 | ||
(5) | flat contact housing with contact locking mechanism |
X | 8K0 973 706 | ||
(5) | flat contact housing | X | 8E0 906 236 | ||
connector housing 7 pin
|
7 pin | ||||
6 | flat contact housing | X | 3B0 972 707 | ||
connector housing 8 pin
|
8 pin | ||||
7 | flat contact housing | X | 3D0 972 708 | ||
(7) | flat contact housing with additional contact lock and additional connector housing mountings |
X | 3B7 035 444 A | ||
(7) | flat contact housing with contact locking mechanism |
X | 3B7 035 447 | ||
(7) | flat contact housing with contact locking mechanism |
X | 3B0 972 724 | ||
(7) | flat contact housing with contact locking mechanism |
X | 1J0 972 724 | ||
connector housing 10 pin
|
10 pin | ||||
8 | flat contact housing with contact locking mechanism |
X | 6R0 972 930 | ||
(8) | flat contact housing | X | 6R0 972 930 A | ||
(8) | flat contact housing with additional contact lock and additional connector housing mountings |
X | 8X0 035 444 | ||
(8) | flat contact housing with contact locking mechanism |
X | 1K0 972 776 | ||
connector housing 12 pin
|
12 pin | ||||
9 | flat contact housing with contact locking mechanism |
X | 8E0 972 112 B | ||
(9) | flat contact housing with contact locking mechanism |
X | 8X0 035 447 | ||
(9) | flat contact housing with contact locking mechanism |
X | 8X0 035 447 A | ||
(9) | flat contact housing with contact locking mechanism |
X | 8X0 035 447 B | ||
connector housing 16 pin
|
16 pin | ||||
10 | flat contact housing with contact locking mechanism |
X | 8E0 972 416 A | ||
(10) | flat contact housing with contact locking mechanism |
X | 1K0 972 928 | ||
(10) | flat contact housing with contact locking mechanism |
X | 4A0 972 883 C | ||
(10) | flat contact housing with contact locking mechanism |
X | 8E0 972 416 | ||
connector housing 20 pin
|
20 pin | ||||
11 | flat contact housing with contact locking mechanism |
X | 8E0 972 420 B | ||
(11) | flat contact housing with contact locking mechanism |
X | 1K0 971 975 | ||
(11) | flat contact housing with contact locking mechanism |
X | 8E0 972 420 | ||
connector housing 26 pin
|
26 pin | ||||
12 | flat contact housing with cap |
X | 4E0 972 726 | ||
(12) | flat contact housing with cap |
X | 7M3 972 726 A | ||
connector housing 30 pin
|
30 pin | ||||
13 | flat contact housing with cap |
X | 3C0 973 763 B | ||
connector housing 32 pin
|
32 pin | ||||
14 | flat contact housing with cap |
X | 1J0 972 977 D | ||
connector housing 50-pin
|
50-pin | ||||
15 | flat connector housing control unit for airbag |
X | 1K0 973 206 | ||
connector housing 52 pin
|
52 pin | ||||
16 | flat contact housing with contact locking mechanism |
X | 1K0 937 702 F | ||
(16) | flat contact housing with contact locking mechanism |
X | 1K0 937 702 E | ||
(16) | flat contact housing with contact locking mechanism |
X | 1K0 937 702 D | ||
connector housing 100 pin
|
100 pin |